MCi Designplan GROUND LINER ETL Installation Instructions Manual page 14

Table of Contents

Advertisement

GROUND LINER®ETL
RGB
CONNECTIONS
DMX 512-A more than 5 luminaires
A
DMX Ampli er
2
DMX
3
Output
4
Maximum 5 luminaires of 1m. per DMX output with PSU 24V
DC - 320W
Maximum 100 meters from controller to rst luminaire
Maximum 100 meters from ampli er to last luminaire
24+
(White)
GND-
(Black)
DMX+
(Brown)
DMX-
(Blue)
M030360
This connection to be
made inside outer body
NOTE:
All wiring outside of outer
bodies
must be run thru conduit!
DMX Controller
GRUPO
MCI
DMX CONTROLLER
DMX
Output 1
24V DC
This connection to be
made inside outer body
M030360
Remote power supply
to be connected to fixtures
inside a nema style (or equal)
enclosure (by others), using
appropriate wirenuts.
PSU 24V DC - 320W
DATA
B
Maximum 5 luminaires of 1m. per DMX controller with PSU
24V DC - 150W
Maximum 100 meters from controller to rst luminaire
Follow connection diagram type
This connection to be
made inside outer body
M030360
DMX 512-A up to 5 luminaires
DMX Controller
GRUPO
MCI
DMX CONTROLLER
for DALI installations
B

Advertisement

Table of Contents
loading