6.2 Change of Static Pressure
The static pressure can be selected by changing the Dip Switches on the electrical board.
Static Pressure Setting:
Dip Switch S2
Blower Speed Tap Fan Speed Select
Setting
ON
OFF
ON
OFF
ON
OFF
ON
OFF
NOTE: Symbol "
" indicates the position of the dip switch.
" indicates any position for ON or OFF.
Symbol "
Dip switch S1 is for production detection, keep its default state.
7. Test Run
Please perform the test run according to the installation manual of the outdoor unit.
2
Medium Low
Medium
3
(Default Setting)
4
Medium High
5
High
Installation and Maintenance
Static Pressure
(W.C.[kPa]) 24K
0.1[0.02]
0.18[0.045]
0.25[0.8]
0.4[0.11]
9
Static Pressure
Static Pressure
(W.C.[kPa]) 36K
(W.C.[kPa]) 60K
0.1[0.02]
0.24[0.057]
0.28[0.07]
0.5[0.12]
0.8[0.2]
0.1[0.02]
0.5[0.12]
0.8[0.2]