INTRODUCTION
HARTELL condensate pumps are designed to collect and automatically remove the water produced
from an air conditioner evaporative coil and/or a gas-condensing furnace. This pump has been
carefully engineered to provide long, trouble free service and is of the highest quality workmanship
and materials.
These pumps have been thoroughly inspected and tested, then carefully packaged to insure safe
delivery and operation. When you receive your pump, examine it carefully to determine that there
are no damaged or broken parts. If damage is detected, notify the firm from where the pump was
purchased. They will assist with a repair or replacement.
See the precautions listed below before continuing
CAUTION: READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION
- Pump should only be used with liquids compatible with pump component materials. Do not use to pump flammable or
explosive fluids. Do not use in explosive atmospheres.
- The pump is supplied with a grounding type plug. To reduce the risk of electrical shock be certain that it is connected to
a properly grounded, grounding receptacle.
- In any installation where property damage and/or personal injury might result from an inoperative or leaking pump
due to power outages, discharge line blockage, or any other reason, a back up system(s) (aux. switch) and/or alarm
should be used.
- Do not handle pump with wet hands or when standing on a wet or damp surface, or in water.
- Shut off the electrical power at the fuse box before making any connections. All wiring must comply with local codes.
HARTELL KT15 and KL20 series condensate pumps are guaranteed to be free from defects in workmanship or
materials and to function satisfactorily, when properly installed, for a period of ONE (1) years from date of installation.
HARTELL will replace, without charge, any HARTELL product found to be defective upon examination at our factory if
returned within the guarantee period, transportation charges prepaid.
This guarantee does not apply if the product has been misapplied or mechanically damaged, HARTELL assumes no
liability for resultant damages of any kind arising out of the use of its products.
.
ONE YEAR LIMITED WARRANTY
I N S T A L L A T I O N
O
P
E
R
A
M A I N T E N A N C E
Hartell Pumps
Division of Milton Roy Co.
70 Industrial Drive
Ivyland, PA
18974
T
I
O
N
Phone: 215-322-0730
Fax: 215-322-2944
Web: www.hartell.com
Email: info@hartell.com

Advertisement

loading

Summary of Contents for Hartell Pumps KT15

  • Page 1 ONE YEAR LIMITED WARRANTY HARTELL KT15 and KL20 series condensate pumps are guaranteed to be free from defects in workmanship or materials and to function satisfactorily, when properly installed, for a period of ONE (1) years from date of installation.
  • Page 2 INSTALLATION Carefully unpack the pump and select a mounting location on the wall, the case of the air conditioner, or floor. The pump must be level and the inlet must be below the lowest drain, either coil or furnace. If wall or case mounting, use the mounting tabs on either side of the reservoir to secure the pump.
  • Page 3 - Check the level of water in the reservoir; the level must be within 2” of the reservoir top to activate the switch. (The inlet tube may be blocked and require cleaning if no water is entering the reservoir). - If there is a proper amount of water in the reservoir, the float may be stuck due to dirt or algae formation. (Flush the reservoir with warm water and a mild soap or detergent).

This manual is also suitable for:

Kl20