Electrical Connection - Miele DA 2808 Operating And Installation Instructions

Table of Contents

Advertisement

For operation with an external motor,
noise from the motor outside the house
and inside the kitchen can be
minimised.
Positioning the silencer in front of the
external motor  reduces noise inside
the kitchen. If the exhaust ducting is
long, the silencer needs to be
positioned at the exhaust duct in the
ducting above the cooker hood itself .
For an external motor installed inside
the house, noise from the motor outside
the house can be reduced by
positioning the silencer behind the
external motor .

Electrical connection

This cooker hood is supplied for
connection to an AC 230 V ~ 50 Hz
supply. It must be connected to an
earthed socket which complies with
relevant regulations.
The electrical installation must comply
with VDE 0100 requirements (BS 7671
in the UK).
For increased safety you should protect
the appliance with a suitable Residual
Current Device (RCD) with a current trip
of 30 mA.
It is recommended that you connect the
appliance via a suitable socket . The
socket should be easily accessible after
the appliance has been installed.
If the socket is no longer accessible
after installation, an additional means of
disconnection must be provided for all
poles. Suitable means of disconnection
include switches with an all-pole
contact gap of at least 3 mm.
These include miniature circuit
breakers, fuses and contactors
(EN 60335).
The relevant connection data can be
found on the data plate (see "After
Sales/Warranty"). Ensure that this data
matches the voltage and frequency of
your household power supply.