Disassembly Procedure - WEG CVW-300 Assembling Manual

Signal conectors kit kcs-300
Table of Contents

Advertisement

Available languages

Available languages

8.9 N to be sure of the retention fingers are holding
the contact.
(a)
Pull back
on wire
3. After all required contacts have been inserted, the
wedge lock must be closed to its locked position.
Releasing the locking latches by squeezing them
inward.
4. Slide the wedge lock into the housing until it is flush
with the housing.

5 DISASSEMBLY PROCEDURE

The plug must be disassembled (contacts removed)
as it follows:
1. Insert a 4.8 mm wide screwdriver blade between the
mating seal and one of the red wedge lock tabs.
2. Pry open the wedge lock to the open (as shipped)
position.
3. While rotating the wire back and forth over a half turn
(one-quarter turn in each direction), gently pull the
wire until the contact is removed.
For further details about the conectors, please refer
to www.te.com.
Signal Conectors Kit KCS-300
(c)
Squeeze locking latches to
seat wedge lock (both slides)
Wedge lock flush
with housing
(b)
Retention fingers
holding contact
Wedge
lock tab
CVW300 | 7