Mitsubishi Electric MELSEC FX Series Structured Programming Manual page 85

Hide thumbs Also See for MELSEC FX Series:
Table of Contents

Advertisement

FXCPU Structured Programming Manual
(Application Functions)
Program example
In this program, float (single precision) data stored in a device specified in
[signed] data, and the data obtained by conversion is output to a device specified in
1) Function without EN/ENO(REAL_TO_DINT)
[Structured ladder]
g_real1=65000.5
[ST]
g_dint1 := REAL_TO_DINT(g_real1);
2) Function with EN/ENO(DINT_TO_TIME_E)
[Structured ladder]
g_bool1
g_real1
[ST]
g_bool3 := REAL_TO_DINT_E(g_bool1, g_real1, g_dint1);
REAL_TO_DINT
g_dint1=65000
a_real
REAL_TO_DINT_E
g_bool3
EN
ENO
a_real
g_dint1
5 Applied Functions
5.1 Type Conversion Functions
is converted into double word
s
.
d
1
2
3
4
5
6
A
83