Program example
In this program, word [signed] data stored in a device specified in
data obtained by conversion is output to a device specified in
1) Function without EN/ENO(INT_TO_BCD)
[Structured ladder]
g_int1=5923
[ST]
g_word1 := INT_TO_BCD(g_int1);
2) Function with EN/ENO(INT_TO_BCD_E)
[Structured ladder]
g_bool1
g_int1
[ST]
g_bool3 := INT_TO_BCD_E(g_bool1, g_int1, g_word1);
INT_TO_BCD
g_word=16#5923
_INT
INT_TO_BCD_E
g_bool3
EN
ENO
_INT
g_word1
5.1 Type Conversion Functions