Time_To_Dint(_E) - Mitsubishi Electric MELSEC FX Series Structured Programming Manual

Hide thumbs Also See for MELSEC FX Series:
Table of Contents

Advertisement

FXCPU Structured Programming Manual
(Application Functions)

5.1.45 TIME_TO_DINT(_E)

Outline
This function converts time data into double word [signed] data, and outputs the data obtained by conversion.
1. Format
Function name
TIME_TO_DINT
TIME_TO_DINT_
E
*1.
Output variable
2. Set data
Variable
EN
Input
variable
_TIME (
ENO
Output
variable
*1
In explanation of functions, I/O variables inside ( ) are described.
Explanation of function and operation
This function converts time data stored in a device specified in
outputs the data obtained by conversion to a device specified in
20m34s567ms
Time data
Cautions
1) Use the function having "_E" in its name to connect a bus.
2) When handling 32-bit data in structured programs, you cannot specify 16-bit devices directly, different
from simple projects. Use labels when handling 32-bit data.
You can specify 32-bit counters directly, however, because they are 32-bit devices.
Use global labels when specifying labels.
126
FX
3U(C)
Expression in each language
Structured ladder
TIME_TO_DINT
Label 1
_TIME
X000
TIME_TO_DINT_E
EN
Label 1
_TIME
Execution condition
Conversion source time data
)
s
Execution status
Double word [signed] data after conversion
(
)
d
1234567
Double word [signed] data
FX
FX
FX
3G
2N(C)
1N(C)
TIME_TO_DINT(_TIME);
Example:
Label 2:=
*1
Label 2
TIME_TO_DINT(Label 1);
TIME_TO_DINT_E(EN,_TIME,
Output label);
Example:
ENO
TIME_TO_DINT_E(X000,Label 1,
*1
Label 2
Label 2);
Description
d
5 Applied Functions
5.1 Type Conversion Functions
FX
FX
/FX
FX
1S
U
2C
ST
Data type
Bit
Time
Bit
Double Word [signed]
into double word [signed] data, and
s
.
FX
0N
0(S)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx-kp-ok-e09r927

Table of Contents