EWELLY EW-T207Z Directions

EWELLY EW-T207Z Directions

Microcomputer thermostat

Advertisement

Quick Links

Microcomputer Thermostat Serial
《EW-T207Z
ELIWELI is an enterprise which is specialized in
producing eletronic temperature controller. We always
insist that quality of product and best service is our goal.
Our sensor is especially precisely made and sealed; it
is moisture-proof , therefore its performances are more
stable and reliable.

Technical Specifications

1、
Operating Voltage
:Load relay: 30A/220V/AC,Directly
2、
Output
Load
used below 30A load.
Defrost relay
5A/220V/AC
3、
Power Consumption
4、
Working Environment
:-50.0℃ ~50.0℃
5、
Control Range
:0. 1℃
6、
Resolving Power
:one- way temperature sensor,one- way
7、
Input Signal
deforsted sensor,10k × 2 m standard cable length
8、
Overall Dimension
:71(W)×29(H)mm
9、
Starter Size
h
Plane Sketc
Refrigerating Indicator
Fan Indicator
Current Temperature
PV
SV
Setting Indicator

Operation Instructions

1、
Setting of control temperature: Press
temperature, pres
or
2、
Setting of parameters: Press
or
to enter input of menu password for inputting the password (if the
password is wrong, you can only see set values of the parameters, which can't
be changed, and the password
procedure, that is,
will appear, and then continuously press
following parameter values will appear:
entering the menu for resetting the parameters.
3、
Display temperature of the defrosting sensing head: Press
temperature of the defrosting sensing head.
Directions
:AC220V ±10%
50HZ/60HZ
、Fan relay 5A/220V/AC
: ≤3W
: -10℃~50℃ RH ≤90%
:±0.5℃
Accuracy
:78(W)×35(H)×62(D)mm
Defrosting Indicator
Fault indicator
Forcible Defrosting Key
C
F
Locking Indicator
to display the control
to change the control temperature.
for 6s,
will appear, and then press
is concealed), press
to enter setting
4、
Enforcing defrosting button: Press
(if temperature of the defrosting sensing head is met (defrosting conditions at ending
temperature of defrosting), enforcing defrosting can be executed).
5、
Press
this time, all parameter values are restored to factory values, 10s later, the system
will be returned to normal operation mode.。

Display instructions

C
C
PV
PV
F
F
SV
SV
C
PV
F
SV
C
PV
F
SV
C
PV
F
SV
C
PV
F
SV
C
PV
F
SV
C
PV
F
SV
C
PV
F
SV
C
PV
F
SV
C
PV
F
SV
C
PV
F
SV
C
PV
F
SV
C
PV
F
SV
Setting Key
C
PV
F
SV
C
PV
F
SV
C
C
PV
PV
F
F
SV
SV
the
Failure display:
C
PV
F
SV
to display
C
PV
F
SV
for a long time for enforcing defrosting
for 1s, and press
for 6s at the same time, the display is flashed, at
Press
for 6s, input correct password, 6s later, press
to modify the setting for low-temperature warning:
-50.0℃~ control temperature of - 1.0℃
press
again
and press
setting for high-temperature warning, to control the
temperature from +1.0℃ to 50.0℃.
Press
again, and then press
returning difference of the temperature: 0.1-15.0℃.
Press
again, and then press
delayed starting: 0-10min.
Press
again, and then press
temperature correction values: -10.0℃ - 10.0℃.
Press
again, and then press
temperature correction values of the defrosting sensor:
- 15- 15℃.
Press
again, and press
01 for modifying types of defrosting.
Press
again, and press
defrosting time: 1-60 min.
Press
again, and press
of defrosting: 0-99h.
Press
again, and press
temperature for defrosting: 0- 40℃.
Press
again, and press
mode of the electric fan
Press
again, and press
dropping time after defrosting: 0-10min.
Press
again, and press
operation mode of the fan after defrosting: 00-01.
Press
again, and press
delayed starting time of the fan after defrosting: 0-20
min.
Press
again, and press
delayed starting temperature of the fan after defrosting:
- 20- 20℃.
Press
again, and press
of the password.
Failure display for super-high temperature
Displays for failures of super-low temperature
or the sensor
Version:T207Z.13.09.24
or
.
or
to modify the
or
to modify
or
to modify
or
to modify
or
to modify
t
or
o select 00 or
or
to modify the
or
to modify period
or
the ending
or
t
o select starting
00-01。
or
to modify water-
or
to select
or
to modify
or
to modify
or
to modify setting

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EW-T207Z and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EWELLY EW-T207Z

  • Page 1 1s, and press for 6s at the same time, the display is flashed, at Microcomputer Thermostat Serial this time, all parameter values are restored to factory values, 10s later, the system 《EW-T207Z 》 Directions will be returned to normal operation mode.。...
  • Page 2 00~60 Minutes Wiring diagram Hours Defrosting period 00~99 Ending temperature Mode:EW-T207Z ℃ 00~40 for defrosting 0 0 = A l w a y s o p e r a t i o n Starting mode of the fan 01=Synchronized operation Water-dropping time 00~10...

Table of Contents