When stoking:
Each time fresh wood is put in the stove, a precise amount of primary air will be allowed in for
the first few minutes. What's more important is that the primary air is not allowed in for too
long. This is to ensure optimum combustion.
The Aduro-tronic control will ensure intake of primary air at the right tempo.
When the Aduro-tronic is set to automatic, it is activated by pulling the primary damper out each
time fresh wood is put in the stove. The automatic closes then the primary air gradually.
Regulation of the Aduro-tronic control:
The control is pre-set to allow primary air intake for the first 5 minutes. This setting has been
used during testing at the Danish Technological Institute using 'standard' sized logs and with
optimum moisture content of 17-20%. Standard size logs are approx. 30 cm long and 10 x 10 cm
in thickness. A standard chimney was also used for testing.
In practice, such circumstances can differ, which is why the Aduro-tronic control can be adjusted
to your circumstances.
If you want a slower intake of primary air: (e.g. for a slower flue draught, larger sized wood or for
longer intervals between stoking)
Adjust the screw on the front of the control level using a small screwdriver to slow closure rate.