Carel thT THB000AAF0 User Manual

Carel thT THB000AAF0 User Manual

Electronic thermostat for residential applications
Hide thumbs Also See for thT THB000AAF0:

Advertisement

thT
Electronic thermostat for
residential applications
Manuale d'uso
User manual
I n t e g r a t e d
C o n t r o l
S o l u t i o n s
F o r
E n e r g y
S a v i n g s

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the thT THB000AAF0 and is the answer not in the manual?

Questions and answers

Summary of Contents for Carel thT THB000AAF0

  • Page 1 Electronic thermostat for residential applications Manuale d’uso User manual I n t e g r a t e d C o n t r o l S o l u t i o n s F o r E n e r g y S a v i n g s...
  • Page 3 CAREL S.p.A. o le sue filiali/ qualora non siano state seguite le avvertenze o raccomandazioni descritte affiliate siano state avvisate della possibilità...
  • Page 5 Content GENERAL FEATURES 1.1 Models ........................7 1.2 Dimensioni ......................7 1.3 Technical specifications................13 “manuale” +03022**** - rel. 0.1 - 00.00.2014 - preliminary version...
  • Page 7: General Features

    1. GENERAL FEATURES 1.2 Dimensioni ThT Thermostat is the CAREL room thermostat that allows users to control the temperature in residential or light commercial environments, providing of simplified interface that is ideal for end users. Temperature Dimension flush mounting set is simple and intuitive, using the knob on the front panel. thT also allows the user to make some settings, such as the operating mode and time bands.
  • Page 8: Cover Dismantling

    • for the serial connection use three-wire shielded cable, AWG 20-22. The Assembly for the wall mounting length of the network must not exceed 500 m. For extended networks 1. Separate the front from the rear of the terminal using a screwdriver; fit a 120 Ohm resistor between RX/TX+ and RX/TX- on the first and last 2.
  • Page 9 Example of network connections AC85~ 250 V 50/60 Hz AC85~ 250 V 50/60 Hz thT - ID51 Power line Power line Digital Load output B(-) Serial B(-) connection A(+) A(+) Dismantling Insert a screwdriver into the clot at the top and press downwards to detach the display.
  • Page 10: Humidity Check

    Display Description Function Parameter If you want to set parameter, you can setting operate as following a. turn off the thermostat b. press and hold “ “ for 5 seconds c. rotate the knob, set the password to 22 d. select parameter and change its value by rotating and press the knob.
  • Page 11: Output Control

    Clock Setting Note: information “hh”, “mm” and “week” is sent by modbus RS485: Turn on the thermostat, press and hold “ “ for 5 seconds, the secondary • hh - Register 6 • mm - Register 7 • day - Register 8 field display “hh:mm”, now , press “...
  • Page 12: Humidity Sensor Calibration

    Auto recovery Description Default Note display value For internal use. It is fix to 1; Password Password is: 22 FAN/HEATING configuration • 00:FAN Key Clock • 01:HEATING Configuration “mode” button Range 1 to 511 To select the sequence of icons to show on display, enter in the Temperature sensor 0.0 °C -5.0 to 5.0 °C...
  • Page 13: Technical Specifications

    1.3 Technical specifications Address Type R or R/W Variable Description Data interpretation Coil R / W Buzzer enable 0: Off Power supply From 85 to 260 Vac, 50/60 Hz 1: Enabled Power consumption 2 VA Coil R / W Time band enable 0: Off Operating Conditions 0 up to +45 °C...
  • Page 14: Address Type

    Address Type R or Variable Description Data interpretation Register R / W Heating button setting 00 Disabled 01 20 minutes 02 40 minutes 03 60 minutes Register R / W hh Time 1 Monday-Friday 00 - 24 Register R / W mm Time 1 Monday- 00 - 59 Friday...
  • Page 16 Agenzia / Agency: CAREL S.p.A. Via dell’Industria, 11 - 35020 Brugine - Padova (Italy) Tel. (+39) 049.9716611 - Fax (+39) 049.9716600 e-mail: carel@carel.com - www.carel.com...

This manual is also suitable for:

Tht thb000acf0Tht thb000aaw0Tht thb000acw0

Table of Contents