NUMBER
NAME
101
PUMP ON DELAY
102
VALVE CLOSE DELAY
103
HIGH PRESSURE MAX
104
CONTINUOUS RUN
TURN OFF TIMER
105
PRESSURE UNITS
106
OIL COOLER OPTION
107
FAN OFF DELAY
108
EMPTY
Operation Manual for PT-1000 & PT-2000
PARAMETERS
DESCRIPTION
THE VALUE ENTERED (SECONDS) IS THE
TIME THAT THE PUMP WILL DELAY TURNING
ON AFTER THE VALVE IS TURNED ON.
THE VALUE ENTERED (SECONDS) IS THE
TIME THAT THE VALVES WILL DELAY CLOS-
ING AFTER THE PUMP IS TURNED OFF.
THE VALUE ENTERED (PSI) IS THE PRES-
SURE THAT WILL TRIP AN ALARM IF THE
PUMP OUTLET EXCEEDS THAT VALUE.
THE VALUE ENTERED (SECONDS) IS THE
AMOUNT OF TIME THAT THE UNIT WILL BE
ALLOWED TO CONTINUOUSLY RUN BEFORE
TIMING OUT AND TRIGGERING AN ALARM.
CHANGE THE UNITS THAT THE PRESSURES
WILL DISPLAY ON THE HMI.
ENABLE THE FUNCTIONALITY/ALARMING
OF THE OIL COOLING UNIT
THE VALUE ENTERED (SECONDS) IS THE
TIME THAT THE COOLING FAN WILL RUN
AFTER THE PUMP IS TURNED OFF
RESERVED FOR FUTURE USE
DEFAULT
RANGE
0.5
0.0 - 10.0
2.0
0.0 - 10.0
2500
0 - 9999
1800
0 - 9999
0: PSI
1: BAR
0: NOT
1: INSTALLED
INSTALLED
120
0.0 - 30
N/A
N/A
Page 11