Dukane iQ Auto-Plus 20AT060-U Series User Manual page 25

Ultrasonic generator/power supply
Table of Contents

Advertisement

Pin 5 (Any Fault Out)
Pin 5 is an isolated digital NPN/PNP status output that
activates whenever any fault condition is detected that
inhibits ultrasound output and normal system operation.
This output will be an open circuit when no system fault
conditions are active.
Pin 6 (U/S Status Out)
Pin 6 is a digital NPN/PNP status output that activates
when the system is delivering ultrasonic power to the load
attached to the ultrasound output connector. This output
will be an open circuit when the ultrasound output is off.
Pin 7 (Output Common)
Pin 7 is electrically isolated from chassis ground. This
common line should be connected to the negative output
of a user-provided isolated 24VDC power supply for a
PLC sourcing input card. For a PLC Sinking input card
this line is connected to the positive output of the isolated
24VDC power supply.
Pin 8 (Remote Setup 0 Input)
Pin 8 represents Setup Bit 0. This is the least significant
bit used to select different probe channels when a Multi-
Probe Control (MPC) Interface is used. This MPC control
bit is used on all MPC systems.
Pin 9 (Remote Setup 1 Input)
Pin 9 represents Setup Bit 1. This is the second least
significant bit used to select different probe channels when
a MPC Interface is used. This MPC control bit is used on
MPC systems with three or more channels.
Pin 10 (Remote Setup 2 Input)
Pin 10 represents Setup Bit 2. This is the third least
significant bit used to select different probe channels when
a MPC Interface is used. This MPC control bit is used on
MPC systems with five or more channels.
Pin 11 (Remote Setup 3 Input)
Pin 11 represents Setup Bit 3. This is the second most
significant bit used to select different probe channels when
a MPC Interface is used. This MPC control bit is used on
MPC systems with nine or more channels.
Dukane Manual Part No. 403-591-01
Pin 12 (Remote Common)
Pin 12 is electrically isolated from chassis ground. Using
sourcing (PNP) output drivers, this common line would
be connected to the automation system ground potential.
Using sinking (NPN) output drivers, this common line
would be connected to the automation system positive
supply voltage output. Refer to Section 6 for wiring
examples to connect input signals.
Pin 13 (U/S Activate)
Pin 13 is used to activate the generator ultrasound output.
Activation of this control input will switch the ultrasound
output ON, and deactivating this signal will switch
ultrasound OFF. This input signal will also function as
a cycle start input, where the ultrasound activation and
timing are completely under the control of the process
controller. Depending on the welding process controller
setup, this input signal could be activated momentarily to
start a welding cycle.
Pin 14 (U/S Common)
Pin 14 is electrically isolated from chassis ground. Using
sourcing (PNP) output drivers, this common line would
be connected to the automation system ground potential.
Using sinking (NPN) output drivers, this common line
would be connected to the automation system positive
supply voltage output. Refer to Section 6 for wiring
examples to connect input signals.
Section 3 – Installation
Page 19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents