Wire Distance (Controller to Valve)

Below is a chart indicating the maximum wire runs that can be used when installing
Valve Wire Sizing (Maximum One-Way Distance in Feet Between Controller and Valve)
Ground
Control Wire (ft)
Wire Size
18 AWG /
1.0 mm
18 AWG / 1.0
850
mm
16 AWG / 1.2
1040
mm
14 AWG / 1.6
1210
mm
12 AWG / 2.0
1350
mm
10 AWG / 2.5
1460
mm
8 AWG / 3
1540
mm
6 AWG / 4
1590
mm
Hunter AC solenoids and valves.
16 AWG /
14 AWG /
1.2 mm
1.6 mm
1040
1210
1340
1650
1650
2150
1920
2630
2150
3080
2330
3450
2440
3700
Copyright 2020 Hunter Industries. All Rights Reserved.
12 AWG /
10 AWG /
2.0 mm
2.5 mm
1350
1460
1920
2150
2630
3080
3390
4170
4170
5400
4880
6670
5400
7690
8 AWG / 3
6 AWG / 4
mm
mm
1540
1590
2330
2440
3450
3700
4880
5400
6670
7690
8700
10530
10530
13330