GB
10. 12 Volt compressor
10.1 Inflating tyres
Please note. Use an air pressure measuring device
to measure the actual tyre pressure. Always observe
the operating instructions when inflating the tyres.
1. Remove the valve cap from the valve.
2. Open the accessory storage compartment and
connect the spiral air hose to the compressor
hose.
3. Screw the connecting part of the spiral air hose to
the car tyre valve.
10.2 Inflation of air mattresses etc.
Important! Because of the material composition of
air mattresses, dinghys etc, no exact air pressure
indication can be given. Therefore make sure not to
inflate these objects too far, as they could burst.
Choose the appropriate adapter and screw this
onto the connecting part of the air hose.
10.3 Starting the compressor
Important! Before starting the compressor, please
read the "important notes" under point 1. After 10
minutes compressor runtime, a cooling off phase of
20 minutes is necessary.
Before switching on, test the pressure gauge
(Fig.1 Item 9).
To switch on, move the ON/OFF switch (Fig.
1/Pos. 11) to ON (I).
To switch off, push the ON/OFF switch (Fig.
1/Item 11) to 0.

11. Voltage transformer

11.1. Before starting the equipment
Before you connect the appliance to the mains
supply make sure that the data on the rating plate
are identical to the mains data of the 230 V
consumer.
Always pull the power plug before making
adjustments to the 230 V consumer.
Notes:
Observe the values from the provided output and
peak output rating (startup rating). Appliances
with higher power requirements must not be
connected.
Please note that appliances with an electric motor
(e.g. drills, etc.) need a significantly higher startup
rating than indicated on the rating plate. For this
reason it may be necessary to switch the voltage
transformer on and off several times. If the 230 V
consumer still does not start up, it cannot be used
16
19.06.2009
11:06 Uhr
Seite 16
because of the high startup rating.
Only one 230 V consumer is permitted to be
connected to each socket.
The use of multi-sockets is not permitted.
Features:
Surge protection / short circuit-protection
Undervoltage protection
Overheating guard
Acoustic alarm
11.2 Operation
11.2.1 Switching the voltage transformer
ON / OFF
To switch ON, push the ON/OFF switch (Fig.
2/Item 13) into position "ON" (I). The red LED
lights up, the voltage transformer is switched on
and ready for operation.
To switch OFF, push the ON/OFF switch into
position OFF (0). The red LED goes out, the
voltage transformer is switched off.
11.2.2 Switching off in case of error
Under the following circumstances the voltage
transformer automatically switches off:
Input voltage is lower than 10-10.5 V
The appliance overheats.
In these situations, switch OFF the appliance using
the ON/OFF switch and remove the attached 230 V
consumer. Check whether all of the ventilation
openings on the voltage transformer are clear and
switch the voltage transformer back on after about 10
minutes waiting time.

12. Care and maintenance

When carrying out cleaning or servicing, the
energy station must be switched off and all
connections must be removed from the
appliance.
Use a soft dry cloth to clean the surface, and do
not use any caustic solvents. If completely
necessary, you can remove dirt with a slightly
damp cloth.
13. Repairs
Only let an authorised expert from a customer
services workshop test the appliance if there are
possible errors.

Hide quick links: