46 | EPS 625 | Product description
i
Ensure that the correct slot on the cam plate is
engaged to avoid free rotation of the swivel plate
(Fig. 1, Pos. 20).
The quantity of test oil fed into the measuring glasses is
controlled by the movement of a stroke valve. The di-
rection and movement of the stroke is governed by the
electronic control unit of the bench.
The test oil is routed back from the MGT to the tank via
the hose (Fig. 5, Pos. 3).
Horizontal MGT adjustment
3
Fig. 6:
MGT height adjustment mechanism
1 Bush
2 Screws for fixing the slide bottom
3 Screws for fixing the vertical guide
4 Locking screw for MGT vertical movement
The MGT is pivoted on a swing arm and can be swiv-
elled 15
on either side by loosening the locking screw
o
(Fig. 6, Pos. 4).
To move the MGT horizontally, loosen the screws
(Fig. 6, Pos. 2) and the nuts and slide the MGT along
the swing arm. The maximum horizontal movement pos-
sible is 150 mm.
i
The swing arm is located under the pump mounting
bed. It can be rotated 180
be operated from either side (left hand side or right
hand side).
|
1 689 988 262
2017-12-26
1
4
2
so that the EPS 625 can
o
Vertical MGT adjustment
To move the MGT vertically, loosen the screw
(Fig. 6, Pos. 3). Then, rotate the hexagon bush
(Fig. 6, Pos. 1). The MGT can traverse 150 mm vertically
to adjust the height for different lengths of high pres-
sure pipes. The swing arm can be fixed in the required
position by tightening the allen bolt on the clamping
piece
3.5.6

Control cabinet

DANGER: Risk of electric shock from live
parts
Touching live parts in the control cabinet
might result in shock and fatal injury or
death.
Work in the control cabinet is only to be
performed by qualified electricians or au-
thorized personnel under the supervision
of a qualified electrician.
Cover or cordon off live parts.
All the electrical components and control elements
required for operation are located in the control cabinet
(Fig. 7). The control cabinet is fixed to the test bench
frame.
Robert Bosch GmbH