Dri-Eaz DrizAir 1200EB Owner's Manual

Dri-Eaz DrizAir 1200EB Owner's Manual

Portable dehumidifier

Advertisement

Tel: +44 (0)1908-611-211 Fax: +44 (0)1908-611-363 www.legendbrandseurope.com
DrizAir
®
1200EB dehumidifiers reduce humidity in enclosed structural environments by
removing water vapor from the air. The 1200EB is engineered to be rugged, durable and
highly portable, making them ideally suited for water damage restoration, structural drying,
construction, and other applications requiring temporary, high-performance
dehumidification.
R E A D A N D U N D E R S T A N D B E F O R E O P E R A T I N G

SAFETY INSTRUCTIONS

WARNING
WARNING! Electric shock hazard, rotating fan
hazard and hot surface hazards.
• Inspect the power cord before use. If cord is
damaged, do not use. Always grasp the plug (not
the cord) to unplug.
• Must be earthed. Insert three-prong plug on power
cord into a matching electrically earthed outlet. Do
not use adapter. Never cut off third prong. Do not
use an extension cord.
• The unit must be operated on a 110V/50 Hz circuit
protected by a Residual Current Device (RCD)
device.
• Keep motor and wiring dry.
• Always unplug unit before cleaning or servicing.
• Do not attempt to repair the unit. For service, contact
your local distributor.
FIRE HAZARD
• Keep away from open flames and heat sources.
• Do not use or store where vapors from gasoline,
solvents, thinners or other flammable materials may
be present.
108248F (07-01502) F203-A 110V UK 1200EB
Owner's Manual
DrizAir 1200EB Portable Dehumidifier
LEGEND BRANDS EUROPE HOLDINGS LTD.
22 Plover Close, Interchange Park, Newport Pagnell, MK16 9PS
Patents: http://www.LBpatents.com
F203-A UK

BEFORE YOU BEGIN

Warranty registration
Warranty registration procedures vary by
country/market. Contact your local distributor for
assistance. Registration allows us to better assist you
with using, maintaining or servicing your equipment and
to contact you in case we have important safety
information concerning your Dri-Eaz product. If you
determine service is required, have your equipment
model, serial number and original proof of purchase
available and ask for assistance with obtaining a return
material authorization (RMA).
GROUNDING INSTRUCTIONS
This unit's plug must be inserted into an appropriate
outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
WARNING! Improper connection of the equipment-
grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or service
person if you are in doubt as to whether the outlets
are properly grounded. Do not modify the plugs
provided with the appliance – if the plugs do not fit
the outlets, have proper outlets installed by a
qualified electrician.
This equipment is for use on circuits with a nominal
rating of no more than 110V.
Handle the unit carefully
Always operate the unit on a stable, level surface. Do
not drop, throw, or place where it could fall. Rough
treatment can damage the unit, and may create a
hazardous condition or void the warranty.
This unit intended for household and commercial use.

INTRODUCTION

Dehumidifiers reduce humidity in enclosed structural
environments by removing water vapor from the air. With
proper use, the 1200EB can help dry carpet, carpet pad,
1
Legend Brands Europe Holdings Ltd.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DrizAir 1200EB and is the answer not in the manual?

Questions and answers

Summary of Contents for Dri-Eaz DrizAir 1200EB

  • Page 1 Registration allows us to better assist you with using, maintaining or servicing your equipment and to contact you in case we have important safety information concerning your Dri-Eaz product. If you determine service is required, have your equipment model, serial number and original proof of purchase available and ask for assistance with obtaining a return material authorization (RMA).
  • Page 2 FIG. A: FRONT damage caused by high humidity. For best results, use Control panel. the 1200EB with Dri-Eaz airmovers placed around the Process (dehumidified) Molded indent perimeter of the room to distribute heat energy and air outlet (not shown).
  • Page 3 Turn the unit on 3. Operation control description Any time the unit is turned off or power is interrupted, the Press the “on” button on the control panel. system initiates a 3-minute delay before the unit can be turned on again. How to use the control panel 3.1 Defrost Function The display panel uses an LCD liquid crystal display...
  • Page 4 “Explanation.” If this still does not fix the problem, Monthly contact your local Dri-Eaz distributor for further Check coils. Dirty coils can cause the unit to overheat. assistance. Clean when visibly dirty. See Fig. B.
  • Page 5 Room temperature is too low. Check filter and coils; replace filter and clean coils as necessary. If the problem you are experiencing is not listed here, call your local distributor or contact your local Dri-Eaz Distributor. SPECIFICATIONS Model...