Exago Manual Contents 1. Safety instructions ..................... 2. Getting started ......................3. Keyboard functions ....................4. B mode and menu ..................... 5. CFM mode and menu ....................6. PW mode and menu ....................7. Measure menu ......................8. Review menu ......................
The device is designed to be operated with a relative humidity range from 10 to The equipment must be used with the 95% including condensation. power adapter supplied by IMV Imaging, The device is designed for the following reference Protek PMP120-13-2-B2. The use atmospheric pressures: of any other power adapter is forbidden.
Page 4
41°C. This equipment can cause electromagne- The Exago device has not been designed tic perturbations and alter the behaviour of to be used together with a high frequency another equipment. It may be needed to surgical device.
2.1 Connection and disconnection of 2.2 Use of Exago trolley probes If the equipment is used with the Exago trolley, check that a probe is connected to To connect a probe, put the probe con- the right hand side connector.
Exago Manual 3.Keyboard functions Keys to navigate through the Report menu menu on screen Shortcut to user defined an- Protocol menu notation with (1-9 as free text) Arrow in active imaging Cine loop records or mode or calipers in allows to view clips Freeze.
The mechanical tolerance of the biopsy guide may exceed the expected values and the guiding channel . Press Biopsy or Clear to remove it. Needle guide only works with recommended IMV Imaging guide for probe. Check that biopsy guide and needle is properly attached to the probe.
Exago Exago Manual Manual 5.CFM mode and menu CFM box position or size can be adjusted using Touchpad or Cursor keys in Pre-trace CFM mode. Date, Time Probe Labels displaying settings of the menu Labels displaying settings of the menu in CFM mode e.g.
Exago Exago Exago Manual Manual Manual 6.PW mode and menu Active PW mode Date, Time Probe Labels displaying settings of the menu e.g WFilter-PW Wall Filter Power label- Power Battery capacity Use keys under “Next/Previous to move along the menu.
Exago Exago Manual Manual 7.Measure menu Freeze the system and access Measure menu. It will automati- cally initiate a first Distance measurement. Date, Time Probe Labels displaying settings of the menu Adjust the calipers positioning with Touchpad and Select. Measurements are displayed on the...
Exago Exago Exago Manual Manual Manual 8.Review menu Review display includes the images and clips list. System will explore USB before exploring the internal memory. In order to access to internal memory, remove any connected USB device. For loaded clips...
Exago Exago Manual Manual 9.Probe menu Access Probe selection (if system used on dual port trolley),Pre-set menu for factory and user-defined pre-set selec- tion. This key is only active when it is in live imaging. Probe Battery capacity Only active if the device is...
Exago Exago Exago Manual Manual Manual 10. Settings User folder Enter user/patient informaton. Duration of scrolling M/PW display. 4 sec by default. Refresh frequency of B image. Freq/Focus: B mode transmit focus and frequency automatically depending on the depth. PW Pre-trace/CFM: displayes the PW gate on active CFM image.
Page 14
Exago Exago Manual Manual System folder Select date format. Select time format. Period in which the system will automa- tically freeze if no key has been used. Time of the day. Improves storing clips on USB flash sticks. Today´s date.
Page 15
Print server Port (default is 104). Provided by the network administrator. Print server Application Entity name. Allocated by the network administrator Exago system application Entity name. Allocated by the network administrator Pallete by default. If not accepted by the server, select RGB or Monochrome.
Exago Manual 11. Protocol menu The menu can be used during an examination or independently of an examination. Click on Patient and select the application and protocol for the examination in “Exam Box. Date, Time Probe Labels displaying settings of the...
Exago Exago Manual Manual 12.Report menu The Report menu allows review of images, clips, reports from USB or internal system me- mory. When no examination in progress When examination in progress Export selected data to Move to the next Export USB Page 1/ external USB device.
Exago Manual 13.Patient menu Access to the menu to review and store Patient data, examination information and Proto- col selection. Choose an application Enter information about owner and patient Review/Store patient data, Patient List exams selection Create a patient. To vali-...
The icon in the lower right part of the screen indicates either the internal me- mory (marked Exago) or on a connected USB. If the indicator is red, the memory is full. During storage of images or clips, the fo-...
Exago Manual 15. Cleaning and disinfection instructions Cleaning and disinfection of the device Before proceeding with any cleaning WARNING: the equipment, check that the system is Do not use alcohol, or other strong switched off and all electrical connections chemicals agents that may damage and peripherals are unplugged.
Page 21
Exago Exago Manual Manual The following disinfection solutions have Dry with a clean and dry cloth. been tested and their compatibility with the components of the probes has been Do not rub the probe with an abrasive proved: sponge. Use a soft cloth or towel.
Exago Manual 16.Probe types and corresponding applications Submerging Limits During cleaning and disinfection of probes, Probe L738P: Submerging limit in a fluid take care of never exceeding the sub- merging limits indicated on the following figures. Probe C360A : Submerging limit in a fluid...
ECOTEXT is useful in predicting the reproductive capacity of young males before entering a center and also in evaluating testicular health in valuable breeders. ECOTEXT has been developed for exclusive use of the EXAGO, with a 7.5 MHz linear rectal probe. http://www.humeco.net/producto/ecotext...
Servicing must be done by IMV imaging authorised service centres. Your equipment should be returned periodically to an IMV imaging service centre. Our qualified service engineers will use special test equipment to thoroughly check the instrument and advise of any work that appears to be necessary.