For your safety operation
The Lynx-CustomFit® Splice-On Connector is designed and
manufactured to assure personal safety. Improper operation
can result in bodily injury and serious damage to this product.
Please read and observe all warnings instructions given in this
operation manual.
Wear safety glasses to protect your eyes when
!
handling optical fiber.
Never look into the end of a microscope or optical
!
cable connected to an optical output device that is
operating. Laser radiation is invisible, and direct
exposure can severely injure the human eye.
Alcohol is flammable, causes irritation and is harmful
!
if swallowed or inhaled. Keep alcohol away from
heat, sparks, skin, and avoid contact with eyes.
In the case of the work at the high place, please be
!
careful not to drop an assembling tool.
Composition
Disposable
Disposable
Holder (*1)
(*1) 1 pc / 100 connectors
Recommended Program
Splicer
Fiber
T-Q101-CA
SMF
(T-71)
MMF
T-QH201e
SMF
(T-201)
MMF
SMF : G.652, G.657
MMF : MM50(OM2), MM50(OM3), MM50(OM4), MM62.5(OM1)
North Carolina (USA)
Sumitomo Electric Lightwave Corp.
78 Alexander Drive, P.O. Box 13445, RTP, NC 27709
TEL +1-919-541-8100
http://www.sumitomoelectric.com/
Copyright © 2011 Sumitomo Electric Industries, LTD.
Lynx- - CustomFit
Lynx
CustomFit® ® Splice
LYNX2- - ST ST for
for 250um
250um or or 900um
Housing
Boot
Parts
Protection
Ferrule
Subassembly
Splicing Program
Heater Program
Lynx
SMF Standard
MMF Standard
Lynx
SMF Standard
MMF Standard
London (UK)
Sumitomo Electric Europe Ltd.
220 Centennial Avenue, Elstree, Herts. WD6 3SL, UK
TEL +44 (0)20-8953-8118
http://www.sumielectric.com/
Splice- - On
On Connector
Connector Ver. 2
900um Tight
Tight Buffered
Installation Manual
Installation
Manual
1. Improper assembly will result in a loss of performance.
Please read instructions given in this operation manual
and the operation manual of the fusion splicer.
2. Never touch the fiber of the stub. It has been inspected
in the factory.
3. The product is sensitive to dirt or dust. Do not take out
any parts from the package until it is to be used.
4. The characteristic will be influenced by the fiber
cleaved surface condition. Please use a cleaver which
has a good cleaving characteristic.
5. Do not remove the dust cap until the connector has
been completely assembled in order not to cause an
high insertion loss due to them.
Either one holder and LYNX2-ST Assembly Tool are required.
Either one holder and LYNX2-ST Assembly Tool are required.
Furcation
for 900um tight buffer
Tube
LYNX2-UML-S
Sleeve
Below equipment or tool are examples.
Fusion Splicer
T-Q101-CA, etc
Holder Type
Please perform Arc test prior to the splicing operation.
(See the operation manual of the splicer.)
*Fiber for testing is not included in the kit.
Please check fiber type inside the field fiber.
Ver. 2
Buffered Fiber
Fiber - -
Precautions
Assembling Tools
Holder (Fiber Side)
for 250um fiber
FHS-09
FHS-025
LYNX2-S-LB5
Fiber Cleaver
FC-6S-C, etc.
.
Cleave length: 10mm
Yokohama (Japan)
Sumitomo Electric Industries, Ltd.
(Lightwave Network Products Division)
1, Taya-cho, Sakae-ku, Yokohama 244-8588, Japan
TEL +81-45- 853-7223, http://global-sei.com/fttx/
LYNX2-ST
Assembly
Tool
Jacket remover
JR-M03, etc.