The staff has experience in handling sample gas as well as in handling electrical and refrigerated devices. AGT-PSG GmbH & Co.KG Page 3 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
Return deliveries must take place in suitable and sound protective packing. Please contact directly the manufacturer AGT-PSG if the sample gas cooler fails. Basis for all warranty claims is the purchase receipt and the undamaged model identification plate. In case of queries we need the model type, serial number and year of construction (model identification plate).
CAUTION! No water! In case of fire, use an approved fire extinguisher. Never use water to extinguish fire (or near the sample gas cooler or directly to the sample gas cooler directed water). AGT-PSG GmbH & Co.KG Page 5 Errors and printing mistakes excepted...
Handle with care. Heavy blows could cause irreparable damage. Only upright vertical position! Lying horizontal position vorbidden! AGT-PSG GmbH & Co.KG Page 6 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
If your sample gas cooler is equipped with condensate connectors at the bottom, always put the housing on ca. 5cm high rails when mounting or moving the cooler. Otherwise protruding condensate connectors at the bottom of the housing can be damaged. AGT-PSG GmbH & Co.KG Page 7 Errors and printing mistakes excepted...
Page 8
(pipe, 12mm outer diameter, without thread). In this case, always put the housing on ca. 5cm high rails when mounting or moving the cooler. Otherwise protruding condensate connectors at the bottom of the housing can be damaged. AGT-PSG GmbH & Co.KG Page 8 Errors and printing mistakes excepted...
Page 9
Optionally they can be designed as stainless-steel bolt joints for 6/4mm hose (drawing B). Beyond that several other connection variants are optionally available. Marking Marking Gas inlet Gas outlet AGT-PSG GmbH & Co.KG Page 9 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
Page 10
We also recommend to use a pre-separator in case of measuring points at high inlet temperatures and high inlet dew points greater than 65°C. The capacity of heat exchangers is thus affected favorably. AGT-PSG GmbH & Co.KG Page 10 Errors and printing mistakes excepted...
WARNING! Automatic start! After you built up the electrical connections, the cooler can start automatically. Remote monitoring connection Electrical connection / Power supply AGT-PSG GmbH & Co.KG Page 11 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
Page 12
(option). If your cooler model is equipped with internal moisture guards, the supply contacts for external moisture guards 4-5 and 9-10 are not active. AGT-PSG GmbH & Co.KG Page 12 Errors and printing mistakes excepted...
Reliable filtration of solid particles (0,1 micron) Optic check of the filtercartridge condition Quick filtercartridge exchange Small dead space Can operate in any installed position AGT-PSG GmbH & Co.KG Page 13 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
Sample gas pre-cooling for inlet dew points >65°C Improved performance of the sample gas cooler Suitable for high temperatures with condensate pump AGT-PSG GmbH & Co.KG Page 14 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
Page 15
Control/alarm for moisture sensor Control alarm for flowmeter light barrier Potential-free directional contact Adjustable switch-point LED for operation/alarm notification AGT-PSG GmbH & Co.KG Page 15 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
Page 16
FEATURES SAMPLE GAS PUMPS Uncontaminated flow Chemically resistant, maintenance-free Application-optimized model types Start/Stop-automatic Perfect integration into the cooler AGT-PSG GmbH & Co.KG Page 16 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
Page 17
(voltage, frequency, gas flow rate, gas inlet temperature, ambient temperature, etc.). WARNING! Open housing! Never operate equipment with panels removed. AGT-PSG GmbH & Co.KG Page 17 Errors and printing mistakes excepted...
(gas flow-rate, gas inlet temperature, gas inlet dew point, ambient temperature, etc.). The cooler must work during the full period of sample gas feed. AGT-PSG GmbH & Co.KG Page 18 Errors and printing mistakes excepted...
Page 19
(for example safety gloves, face mask, safety goggles etc.). CAUTION! Toxic and explosive gases! Corresponding guidelines must be adhered to while operating with toxic and explosive gases. AGT-PSG GmbH & Co.KG Page 19 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
Page 20
MAK10 has a multi-function LCD display, 3 operation status indicators (ALARM, SERVICE, POWER) and 3 buttons (ON/OFF, MODE, SET). CAUTION! Warranty lost! A change of the original setup may lead to a total loss of warranty. AGT-PSG GmbH & Co.KG Page 20 Errors and printing mistakes excepted...
5 min On, 0 min Off. The TLo temperature is displayed again if a keypad input is not given within 10 seconds. AGT-PSG GmbH & Co.KG Page 21 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
Page 22
Sample Gas Pump (Option): A temperature alarm simultaneously switches off the integrated sample gas pump. The sample gas pump starts automatically after annulment of the alarm. AGT-PSG GmbH & Co.KG Page 22 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
(MODE) / Displaying operation modes“). Operating mode Displays the current operating mode. See chapter „Operation buttons“. Condensate pump(s) Condensate pump(s) working. AGT-PSG GmbH & Co.KG Page 23 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
Page 24
Wait for the start-up phase working Temperature-alarm or Find and clear causes of the alarm condensate-alarm (option) Defective sample gas pump Contact AGT-PSG Service AGT-PSG GmbH & Co.KG Page 24 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
CAUTION! Toxic and explosive gases! Corresponding guidelines must be adhered to while operating with toxic and explosive gases. WARNING! Open housing! Never operate equipment with panels removed. AGT-PSG GmbH & Co.KG Page 25 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
After service work is done, reset service interval / operating hours counter acknowledge possible notifications alarm log (see chapter “Temperature-Monitoring and Error-Diagnosis”). AGT-PSG GmbH & Co.KG Page 26 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
The fuse holder can then be removed along with the fuse. The fuse holder is fixed after replacing the fuse and locked in the clockwise direction. AGT-PSG GmbH & Co.KG Page 27 Errors and printing mistakes excepted...
Page 28
By simultaneously pressing (2 sec.) the operation buttons 2-TEMP and 3-MODE the operating hours counter can be reset to zero. The service LED turns off. This action should take place only after proper maintenance of the cooler. AGT-PSG GmbH & Co.KG Page 28 Errors and printing mistakes excepted...
Complete moisture sensor set for external mounting Glass 8440224 Flow chamber PVDF 6353952 Flow chamber Glass 6404050 Sensor 5700000 Electronic control unit EC72.01 for moisture sensor 5201047 AGT-PSG GmbH & Co.KG Page 29 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
Page 30
Thermal transmission paste tube 250g 6938111 Only qualified personnel should perform troubleshooting, maintenance or repair operations. Please contact directly the manufacturer AGT-PSG if the sample gas cooler fails. Tampering the safety and security devices is not permissible. AGT-PSG GmbH & Co.KG...
MAK10 Return / Maintenance and Repair Packaging and Shipping If you want to send a device for maintenance or repair to AGT-PSG, please note the following information on packaging and shipping: Please use the original packaging of the device. If this is not available, use another stable packaging in which the cooler is well protected from the weather and mechanical damage.
Page 32
Liquid Solid Powdery Gaseous Please include the current material safety data sheet of the hazardous material! Company, Contact Location, Date, Stamp, Signature AGT-PSG GmbH & Co.KG Page 32 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
Page 33
Installation-, Operating-, Maintenance-Manual, Spare part List MAK10 Circuit Diagram 230V 50/60Hz and 115V 50/60Hz AGT-PSG GmbH & Co.KG Page 33 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
Page 34
Installation-, Operating-, Maintenance-Manual, Spare part List MAK10 Circuit Diagram Addendum for Sample Gas Pump Option AGT-PSG GmbH & Co.KG Page 34 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
Page 35
RI Flow Schema Scope of supply of MAK10P Heat-exchanger Condensate pump Pre-separator Filter Flowmeter Electronic control unit Moisture sensor MAK10-1101-X-00-X MAK10-1101-X-10-X MAK10-1101-X-11-X MAK10-1101-X-1F-X AGT-PSG GmbH & Co.KG Page 35 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
Page 36
RI Flow Schema Scope of supply of MAK10P Heat-exchanger Condensate pump Pre-separator Filter Flowmeter Electronic control unit Moisture sensor MAK10-1112-X-00-X MAK10-11121-X-11-X MAK10-2202-X-00-X MAK10-2202-X-20-X AGT-PSG GmbH & Co.KG Page 36 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
Page 37
RI Flow Schema Scope of supply of MAK10P Heat-exchanger Condensate pump Pre-separator Filter Flowmeter Electronic control unit Moisture sensor MAK10-2202-X-22-X MAK10-2202-X-1F-X MAK10-2222-X-00-X MAK10-2224-X-22-X AGT-PSG GmbH & Co.KG Page 37 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
Page 38
RI Flow Schema Scope of supply of MAK10P Heat-exchanger Condensate pump Pre-separator Filter Flowmeter Electronic control unit Moisture sensor MAK10-3303-X-00-X MAK10-3303-X-1F-X MAK10-4404-X-00-X MAK10-4404-X-IF-X AGT-PSG GmbH & Co.KG Page 38 Errors and printing mistakes excepted Translation - Manual MAK10 Rev. 11/2017...
Page 39
The temperature control unit monitors the ambient and the dew point temperature but it does not access the power regulation. It provides an alarm at unacceptable exceeding or undercut of temperature as well as at exceeding service intervals. It logs all malfunctions of the cooler. AGT-PSG GmbH & Co.KG Page 39 Errors and printing mistakes excepted...