4

WARRANTY

The manufacturer guarantees the for the period of one year from the
date of purchase, the product will be free of defects in workmanship
and/or material. As well the manufacturer offers a life time warranty on
the flow through humidifier body. During the warranty period, we will
replace or repair any defective part at no charge if the product is
returned prepaid to our factory.
This warranty does not cover any labor or shipping costs, or the cost of
replacement components as part of routine maintenance (such as Flow
Through Humidifier Evaporator Pads, Inlet water Filters, or Orifice
Fittings). Any damage or failure caused by abuse, misuse, abnormal
usage, faulty installation, or improper maintenance will not be covered
by this warranty.
In order to make a claim on this warranty you must be the original
consumer of the product and you must contact the manufacturer 1-800-
465-7300 between 8 AM and 3:30 PM EST Monday to Friday at the first
sign of a defect. You will be required to present to the manufacturer the
original bill of sale showing date of purchase, place of purchase, and
model purchased. Failure to meet these requirements will void your
warranty.
The manufacturer will not be held responsible for any bodily injuries or
damages to personal property or real estate whether caused directly or
indirectly by the product. Some states and provinces do not allow the
exclusion or limitation of incidental or consequential damages and some
states or provinces do not allow limitations on how long an implied
warranty lasts, so these exclusions or limitations may not apply to you.
This warranty gives you specific legal rights and you may have other
rights which vary from state to state and province to province.
SAVE THIS DOCUMENT AND ATTACH YOUR RECEIPT.
Date of Purchase
Place of Purchase
See attached table regards specific component warranty periods.

MAINTENANCE

REPLACING/REMOVING THE EVAPORATOR PAD. (REFER TO FIGURES
1 A, B, C)
In order to ensure maximum performance you should replace the
evaporator pad at least once a year, Depending on the condition of your
water you may want to consider more frequent replacement.
1. Turn off the power to the humidifier, Turn off the water supply to the
humidifier, Turn off your furnace.
2. Remove the humidifiers front cover it is secured in place with a thumb
screw.
3. Remove the flexible water supply tube from the water nozzle at the
Date Of Installation
Brand and Model#
top of the distribution tray, it is press fit in place.
4. Remove the distribution tray two hooks at the top of the unit secure it in
place. Lift up on the hooks and carefully slide the tray out. As the tray
comes out the evaporator pad may come with it.
5. If the pad does not come out with the distribution tray you may
remove it now.
The evaporator pad is held in place by the
distribution tray.
6. Now that the pad is out you may inspect, and or replace with a new
one. It is important that the black spot on the evaporator pad be at
the top.
7. Position the new pad in place bottom first. On the inside of the
humidifier, at the bottom is a trough used to collect draining water.
In the front of the trough are 2 tabs on either side, the evaporator pad
sits behind the 2 tabs.
8. With the pad position correctly at the bottom the distribution tray can
be reinstalled. Make sure that the water nozzle inlet (at the top of the
distribution tray) is facing out. Tilt the pad away from the top of the
unit and position the distribution tray on top of the pad. Guide the
distribution tray into the side channels at the same time deflecting the
2 hooks which secure the distribution tray in place.
9. Carefully push the distribution tray all the way back until the 2 hooks
engage the front edge of the distribution tray.
10. Reinstall the flexible water supply tube into the water nozzle at the
top of the distribution tray, it is press fit.
11. Replace the humidifier's front cover and secure with thumb screw.
12. Turn on the power to the humidifier, Turn on the water supply to the
humidifier, Turn on your furnace.
A
REPLACING/REMOVING THE INLET WATER FILTER
(REFER TO FIGURES 2 A, B, C)
The purpose of the inlet water filter is to protect the humidifier's orifice
fitting (which meters water usage) and the solenoid valve, it stops solids
from plugging those components. This filter should be checked if you
notice that the amount of water being supplied to the humidifier has
reduced. If you live in an area with hard water (high mineral content)
you may want to consider replacing this filter yearly. This filter is
available through our Parts and Service line 1-800-465-7300.
1. Turn off the power to the humidifier, Turn off the water supply to the
humidifier, Turn off your furnace.
2. Remove the bypass tube from the side of the humidifier, 6" spring
clamp secures it in place.
3. Using a wrench remove the water supply tube from the solenoid
valve.
4. The inlet filter is located inside the solenoid valves inlet. Using a
Figure 1.
B
C