Operating The Fire - Dimplex Verdi Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14
Connecting the Transducer Unit + Lamps
1. Release the two red tabs by turning them by 90 degrees (Fig 2)
2. Lift out the Sump Nozzle (Fig 3)
3. Insert lamps into lamp holders (Fig 4), carefully locating the pins into the holes (Fig 4a)
4. Push lamps irmly into place
5. Place the Transducer Unit into the sump and join the cable to the connector on the sump (Fig 5)
6. To ensure that the Transducer Unit is correctly placed in the sump, the tab on the Transducer Unit should be lined
up with the moulded recess in the sump (Fig 5a).
7. Ensure that the cable is not placed above the disc on the Transducer Unit (Fig 5b). To prevent the cable becoming
pinched between the nozzle and the sump, place the cable in the slot in the wall of the sump.
8. Replace the Sump Nozzle and secure it by turning the two red tabs by 90 degrees (Fig 6)
Filling the Water Tank
9. Place Water Tank in sink and remove cap (turn anti-clockwise to open) (Fig 7)
10. Fill Water Tank with decalciied tap water only. This is necessary to prolong the life of the lame and smoke
producing unit. The water should be iltered through a conventional domestic water ilter unit and the ilter should
be replaced regularly.
11. Screw the cap back on – do not overtighten.
12. Place the Water Tank in the Sump, with the tank cap facing down and the lat side of the tank facing outward (Fig 8)
Assembling the ire
13. Place the Fuelbed on top of the Water Tank and Mist Nozzle (Fig 9)

Operating the Fire

This section describes how to activate your ire using either the manual controls or remote control.
MANUAL CONTROLS
The manual controls are located beneath the hinged lap. (Fig.10 for Manual Control lay out)
Switch 'A':- Controls the electricity supply to the Fire.
Note: This switch must be in the 'ON' ( I ) position for the Fire to operate either with or without heat.
once to turn on the lame effect. This will be indicated by an audible beep. Although the main
Switch 'B':- Press
lights operate immediately it will take a further 30 seconds before the lame effect starts.
again to give lame effect and half heat. This will be indicated by two beeps.
Press
again to give lame effect and full heat. This will be indicated by three beeps.
Press
again to return to lame effect only. This will be indicated by one beep.
Press
to put ire in to standby mode. This will be indicated by one beep.
Press
Control Knob 'C':- Controls the Thermostat setting.
Turning the control knob to the left will decrease the temperature setting, turning the control knob
to the right will increase the temperature setting.
Control Knob 'D':- Controls the intensity of the lame effect.
Turning the control knob to the left increases the lame effect, turning the control knob to the right will
decrease the lame effect.
SETTING THE THERMOSTAT
Ensure the ire is plugged in and switch it on to the full heat setting. Turn the Control Knob 'C' fully to the right (max
temperature setting) to warm the room rapidly. When the room temperature has reached the desired level, turn
the thermostat knob back slowly until you hear the thermostat just click off. The heater will then maintain the room
temperature at the chosen level.
Note: Should your heater fail to come on when the thermostat is at a low setting, this may be due to the room
temperature being higher then the thermostat setting
THERMAL SAFETY CUT-OUT
A thermal safety cut-out is incorporated in the fan heater to prevent damage due to overheating. This can happen if
the heat outlet was restricted in any way. If the cut-out operates, unplug the heater from the socket outlet and allow
approximately 10 minutes before reconnecting. Before switching the heater back on remove any obstruction that may
be restricting the heat outlet, then continue normal operation.
Caution: In order to avoid a hazard due to inadvertent resetting of the thermal cutout, this appliance must not be
supplied through an external switching device, such as a timer, or connected to a switch that is regularly switched on
and off by the utility.
GETTING THE DESIRED FLAME EFFECT