Cooling - Hitachi EC702HP Operation Manual

1.4 kw uhf 8vsb-atsc transmitter
Hide thumbs Also See for EC702HP:
Table of Contents

Advertisement

Section 2 - Minimum Installation Requirements
(E-Compact ATSC Transmitters)

2.4.3 Cooling

The air conditioning system should always be operated in the "recirculation" mode, with the
room temperature being reduced without outside air coming in. For improved cooling system
performance, the air conditioner should be installed in series with the transmitter's cooling cycle.
I.e., the air conditioner's outgoing flow must be directed to the front part of Hitachi Kokusai Linear
TV transmitter.
The transmitter's installation layout should contemplate a free space around the transmitter for
higher cooling efficiency and access for maintenance. Refer to the table below for details:
Note: If the transmitter is installed in a rack, the transmitter front and rear must be entirely
unobstructed.
Manual Rev. 0.1 – September 2014
Transmitter
EC701HP
EC702HP
EC703HP
EC704HP
EC706HP
EC708HP
Free internal area
16,0m²
2-6