7-7
SET DOOR2
When connecting door station 2, set "Video", "Audio" or "None
(door station 2 not connected)".
These operations must be performed by an installer. Please
do not change these settings yourself.
1
After performing steps 1 and 2 in section 7-1, select "SET
DOOR2" and press CALL button.
SET DOOR2
7-8
SET DOOR RELEASE
When not connecting the door release, set to "Not use".
These operations must be performed by an installer. Please
do not change these settings yourself.
1
After performing steps 1 and 2 in section 7-1, select "SET DOOR
RELEASE" and press CALL button.
SET DOOR RELEASE
7-9
SET EXTERNAL SENSOR INPUT
When optional units operate (for example, when a sensor detects a
malfunction and CALL button is pressed), the master monitor station and
sub station will receive a notification sound. Further, when
set, door station 1 also receives a notification sound.
These operations must be performed by an installer. Please do not
change these settings yourself.
1
After performing steps 1 and 2 in section 7-1, select "SET
EXTERNAL SENSOR INPUT" and press CALL button.
SET EXTERNAL SENSOR INPUT
7-10

RESTORE DEFAULT SETTING

All settings can be restored to their condition at the time of purchase.
1. Once the settings are initialized, they cannot be restored to their
previous settings.
2. Recorded images, Voice memos, and Messages for the entrance
are also all erased.
Settings reset with "RESTORE DEFAULT SETTING"
Setting name
Time
2006 01 JAN 00 : 00
Screen background color
Black Orange Green Blue
1 (Tone 1)
Door station 1 chime tone
Door station 2 chime tone
1 (Tone 1)
Door station 2
(Video)
(Use)
Door release on or off
External sensor input
(30 seconds)
are the initial values.
JF-2MED
JF-2MED
Available settings
2 (Tone 2)
3 (Tone 3)
4 (Tone 4)
2 (Tone 2)
3 (Tone 3)
4 (Tone 4)
(Audio)
(None)
(Not use)
(Continuous)
(Outdoor output)
2
In the "SET DOOR2" screen, press PLAY button or REC button to
select the type of door station that is connected.
SELECT
SET
3
Press CALL button to complete the settings and return to the
setting screen.
SELECT
SET
2
In the "SET DOOR RELEASE" screen, press the PLAY button or
REC button to select the setting.
When "Not use" is selected, door release symbol is not displayed on
the menu screen. (Refer to section 8-2)
SELECT
SET
3
Press CALL button to complete the settings and return to the setting screen.
SELECT
SET
JF-2MED
JF-2MED
2
In the "SET EXTERNAL SENSOR INPUT" screen, press PLAY button
or REC button to select the notification sound contents.
is
SELECT
SET
3
Press CALL button to complete the settings and return to the setting screen.
SELECT
SET
JF-2MED
1
After performing steps 1 and 2 in section 7-1, select "RESTORE
DEFAULT SETTING" and press CALL button.
RESTORE DEFAULT SETTING
2
In the "RESTORE DEFAULT SETTING" screen, press CALL button
to initialize. Press PLAY button to return to the setting screen.
DO YOU WANT TO INITIALIZE?
3
"INITIALIZING" is displayed. Initializing takes approx. 10 to 20
seconds.
- 9 -
Video door station
Audio door station
Door station 2 not connected
Use
Not use
The notification sound stops after 30 seconds.
The notification sound operates continuously.
The notification sound operates continuously,
and is also sounded at door station 1.