CONTROL STATION

AR2 gear motors are equipped with control station, which works as follows:
6.1
Connect phase L1 to terminal # 1 and neutral N to terminal # 2.
6.2
Set the AUTO/MAN dip-switch on manual position [ON] at the left.
6.3
A red LED will light up to show the manual working way.
6.4
Push red knobs - / + to rotating the shaft clockwise or counterclockwise.
6.5
Re-set the dip-switch onto automatic way [pos. 1 on the right] when manual
calibration is finished. the red LED will light off.
7
PROPORTIONAL OPERATION
7.1
All adjustments are already set at factory. Hence, it is recommended to avoid any
intervention on cams and potentiometer.
7.2
Warning: potentiometer is installed for card balancing purposes ONLY.
Consequently, it is not to be used.
8

MAINTENANCE AND CHECKS

8.1
M
AINTENANCE
AR2 gear motor does not require any particular current maintenance.
8.1.1
AR2 gear motor does not require any lubrication since the gear box is
8.1.2
lubricated at factory.
Avoid any on field reparation.
8.1.3
Do not disassemble any internal part of the AR2...E gear motor. In case
8.1.4
of non-functioning, after having performed all possible checks on field, the
gear motor must be returned to the factory for any possible repair.
Any replacement must be carried out by qualified technicians only.