5 Interfaces
5.8

Digital I/O

The digital I/O interface provides an input and an output group, each containing eight signals. The
input group is electrically isolated from the output group. Both groups are also isolated from oth-
er VisionBox circuits and interfaces.
The following illustration shows the corresponding electrical equivalent circuit:
VisionBox
Galvanic isolation
Current
IN 0
Current
IN 1
IN 7
Current
- / GND
The input group requires an external connection of a shared GND reference. For the output
group, the user must provide a supply voltage to the VCC pin which is used by all output signals.
Every input and output have an LED to show the current state of the channel.
The connector arrangement is shown below:
Figure 12: Digital I/O connector
Mating external plug component: Phoenix Contact MC 1,5/18-STF-3,5 (order no. 1847288)
Limit
Limit
Limit
Figure 11: Simplified digital I/O circuit
IMAGO Technologies GmbH
Strassheimer Str. 45; 61169 Friedberg - Germany; Tel. +49 6031-6842611
info@imago-technologies.com;
Real-Time
Communication
Controller
(FPGA)
Pin
Function
1
OUT 7
2
OUT 6
3
OUT 5
4
OUT 4
5
OUT 3
6
OUT 2
7
OUT 1
8
OUT 0
+ / Common VCC
17
of outputs
Table 4: Pin assignment dig. I/O
www.imago-technologies.com
Page 15 / 22
Galvanic
isolation
+ / VCC
OUT 0
OUT 1
OUT 7
Pin
Function
9
IN 7
10
IN 6
11
IN 5
12
IN 4
13
IN 3
14
IN 2
15
IN 1
16
IN 0
- / Common
18
GND of inputs