General safety regulations
Attention! Mounting, installation, commissioning and repair of electronic devices have
!
to be carried out only by qualified electricians. The standard for the prevention of acci-
dents must be observed!
When working in systems with 230 V mains voltage, the safety requirements according to
DIN VDE 0100 must be observed.
When installing TCS:BUS systems, the general safety regulations for telecommunication
systems according to VDE 0800 must be observed. Inter alia:
separated cabling of heavy and low current lines,
minimum distance of 10 cm for common cabling,
use of separators between heavy and low current lines in shared cable ducts,
use of standard telecommunication lines, e.g. J-Y (St) Y with 0.8 mm diameter,
existing lines (modernisation) with deviating cross sections can be used in compliance
with the loop resistance.
Attention!
Fluids or small electroconductive parts which enter the device can cause a short-circuit,
fire or an electric shock. Please, avoid contacting the device with water or other fluids.
Avoid small electroconductive parts from entering the device (e.g. in the ventilation lou-
vres).
The device produces heat. Ensure a sufficiently ventilation. Do not cover existing venti-
lation louvres.
Installation – protective measures
Outside the device, an easy accessible separating unit for mains separation is neces-
sary.
An overcurrent protective device is to be installed upstream.
The device is to be installed in a way, that the user does not have any direct access to
the area of the mains connection terminal after the installation.
With suitable requirements to protect against lightning, it has to be ensured that a volt-
age of 32 V DC is not exceeded at the connections a, b and P.
The device is conform to the overvoltage category II.
1 x VBVS05-SG
1 x Product information
TCS TürControlSysteme AG: www.tcsag.de
TCS Hotline Germany Mail: hotline@tcsag.de
2
Safety instructions
Scope of delivery
Subject to technical changes.