  • Page 1 Integrated Fire Protection System ® 1230 Owner's Operation and Maintenance Manual Remote Controlled system FM-0860-0-29D...
  • Page 2 Systems Inc assumes no ® liability resulting from any errors or omissions in this manual, or from the use of the information contained herein. 1230 is a registered trademark of F Systems Inc. Systems Inc. reserves the right to make changes to this manual and the data sheets herewith at any time, without prior notification.
  • Page 3: Table Of Contents

    4.1 PRODUCT DESCRIPTION ..............................11 ® 4.2 REMOTE CONTROLLED F 1230 ........................... 11 5. WIRING DIAGRAMS ..............................12 ® 5.1 REMOTE CONTROLLED F 1230 ........................... 12 6. CABINET..................................14 7. LIMITED WARRANTY ..................... ERREUR ! SIGNET NON DEFINI. Remotely Controlled 1230 Engineered FM-0860-0-29D...
  • Page 4 ® 1230 Page iv Integrated Fire Protection System & M WNER PERATION AINTENANCE ANUAL This page is left blank intentionally. FM-0860-0-29D Remotely Controlled 1230 Engineered...
  • Page 5: General

    NFPA-72 Fire Alarm Systems manufacturer design manuals: NFPA-2001 Clean agent fire extinguishing system • SEVO Design Manual: SE 1230 500 ENG (latest rev.) Before the installation, the contractor installing the unit shall The cylinders are filled with the extinguishing agent and then also be familiar with the following documents and standards: pressurized to 500 Psi at 70°F (34.5 bar at 21.1°C) with...
  • Page 6: Features

    The electric releasing condition is needed by an approved • Compact, aesthetic and easy to move releasing control panel in order to operate the electric actuator (C) of the NOVEC 1230. It can be achieved as the • Available in 4 cabinet sizes following: •...
  • Page 7 1230 Page 3 of 16 Integrated Fire Protection System & M WNER PERATION AINTENANCE ANUAL Figure 1.1 - Single NOVEC 1230 cylinder with electric release Field connection to NOVEC 1230 piping 1230 base (shown without enclosure) FM-076Z-0-15B-1 Components: A Cylinder...
  • Page 8 Page 4 of 16 Integrated Fire Protection System & M WNER PERATION AINTENANCE ANUAL Figure 1.2 - Double NOVEC 1230 cylinder with Main / Reserve switch Field connection to NOVEC 1230 piping 1230 base (shown without enclosure) FM-076Z-0-15B-2 Components: A Main cylinder (Reserve is the right one)
  • Page 9 Page 5 of 16 Integrated Fire Protection System & M WNER PERATION AINTENANCE ANUAL Figure 1.3 - Double NOVEC 1230 cylinder with Master / Slave operation Field connection to NOVEC 1230 piping Copper tubing 1230 base (shown without enclosure) FM-076Z-0-15B-3...
  • Page 10: Clean Extinguishing Agent

    Low Observed Adverse 7.5% 2.2 DESCRIPTION Effect Level (LOAEL) Acute Exposure LC50 NOVEC 1230 is a colorless fluid. It is stored as a pressurized 100,000 800,000 (4 hour rate - ppm) liquid and injected into a room, area, or compartment that has...
  • Page 11: Installation, Operation & Maintenance Instructions

    3. Check all releasing conditions. panel (refer to section 5. 4. Check if NOVEC 1230 electric actuator (C) operates 5. Conform to local municipal or other codes regarding after preset time delay.
  • Page 12: Sequence Of Operation

    Note: At any time, if the optional mechanical activator (J) is activated, the NOVEC 1230 will be released. b) Pre-discharge delay starts (not exceeding 60 sec). Note: The abort station will prevent the NOVEC 1230 3.4.3 Abort Station discharge as long as being maintained if activated during 1.
  • Page 13: Emergency Instructions

    Figure 3.3 installed BEFORE installing it on the cylinder valve (B). Normal position 7. Notify the Authority Having Jurisdiction, remote station alarm monitors, and those in the affected area that the system is back in service. Remotely Controlled 1230 Engineered FM-0860-0-29D...
  • Page 14: Inspections & Tests

    Having Jurisdiction upon request. Typical records include, but enclosure. are not limited to, detection system, and NOVEC 1230 cylinder inspections. Acceptance test records should be retained for the life of the system.
  • Page 15: Controls

    Once the left door opened, it give access to the electrical The right door is available only with cabinet greater than 24". junction box and the releasing circuit disabled switch of the NOVEC 1230 (refer to figure 5.1 or 5.2 for additional details). ® 4.2 REMOTE CONTROLLED...
  • Page 16: Wiring Diagrams

    24Vdc source is applied to the electric actuator (C), which will vent the pressure on top of the selected cylinder valve (B) allowing the extinguishing agent NOVEC 1230 to be discharged through the nozzles. 5.1.3 Electric release with Master / Slave operation See figure 5.1.
  • Page 17 Cylinder pressure switch: 2A@28VDC, 375VA@120VAC Discharge switch: 20A@120/240VAC USE ONLY WITH POWER LIMITED CIRCUITS. - End-of-line devices shall be compatible with the release control panel (not included). - NOVEC Actuator P/N SOL EA45 is rated 24VDC, 500mA, Remotely Controlled 1230 Engineered FM-0860-0-29D...
  • Page 18: Cabinet

    ANUAL 6. CABINET ® 1230 cabinet is made of sturdy 14 gauge steel. Figure 6.1 - Drilling details All surfaces are rust proof coated, inside and outside, with fire red, oven baked polyester powder on phosphate base. Cabinet is provided with...
  • Page 19 12¾" 77⅛" 46" 46" 25" 50" 15" 48" 23" 54" 54" 31" 81" 58" 21" 56" 26" Table 2 - NOVEC 1230 piping installation 1" 2¾" 6" 3¼" 1¼" 2¾" 6" 3¼" 1½" 2¾" 6" 1¾" 2" 6¾" 6" 4¾"...
  • Page 20: Limited Warranty

    Toll Free: (866) 347-3353 Web site: http://www.fireflex.com ◊ Email: but not limited to, property damages, personal injury, revenue info@fireflex.com loss or lost profits, inconveniences, transportation charges or other damages suffered by anyone.