Info Information marked with this symbol helps you to carry out your tasks quickly and safely. Follow the manual Information marked with this symbol indicates that the operating manual must be observed. particle counter PC220...
To use the device for its intended use, only use accessories and measurement. For particles larger spare parts which have been approved by Trotec. than the smallest detectable size, the counting efficiency is 100 %. Improper use The device may not be used for measurements in liquids.
Page 4
Do not overcharge lithium-ion batteries. Only use smart chargers that switch off automatically when the battery is fully charged. Charge lithium-ion batteries in due time before they are discharged completely. Caution Keep a sufficient distance from heat sources. particle counter PC220...
Page 5
Exposure results in an effect; headaches possible in case of interaction with other exposure parameters > 25 Headaches; other neurotoxic effects apart from headaches possible (Source: German Federal Environmental Agency, Federal Health Bulletin, B. Seifert, Guideline values for indoor air, Springer 1999) particle counter PC220...
Function keys "F1", "F2" and "F3" Health and Safety. Maintenance and repair work may only be carried out by trained expert staff observing the legal Arrow button up regulations. "ENTER" button "RUN/STOP" button Arrow key down "On/Off" key "ESC" key particle counter PC220...
Page 7
< 95 % RH (non-condensing) Humidity measurement Humidity level measuring 0 % RH to 100 % RH range Humidity level accuracy ±3 % RH at 40 % to 60 % ±3.5 % RH at 20 % to 40 % and 60 % to 80 % ±5 % RH at 0 % to 20 % and 80 % to 100 % particle counter PC220...
Resolution 0.01 ppm external influences. Carbon monoxide (CO) • The storage temperature is the same as the range given in Measuring range 10 to 1000 ppm the Technical data chapter. Accuracy ±5 % FS Resolution 1 ppm particle counter PC220...
Start screen You can open the following menus from the start screen: "F1" button MEMORY SET – saved data "F2" button SYSTEM SET – system settings "F3" button Info – Information about the device "ENTER" "Measurement" screen button particle counter PC220...
Page 10
Measurement in progress / Measurement stopped Select particle size for indicator scale Level Indication Method of analysis/measuring mode: for particle burden HCHO measurement CO measurement Particle measurement cumulative Particle measurement differential Particle measurement concentration Particle measurement mass concentration particle counter PC220...
Page 11
ð The photo is displayed. ð The measurement continues in the background. 3. You can save the photo by pressing "F1" , or delete it by pressing "F3" 4. Press "ESC" to exit the photo function. particle counter PC220...
Page 12
1. Select PARTICLE in the start screen, then press the "ENTER" button. ð The "Measurement" screen opens. 2. Press the "F3" button to open the measurement settings. 3. Use the buttons to select "filter efficiency" and press the "ENTER" button. particle counter PC220...
Trotec assumes no liability with regard to this Cleaning the sensor (internal calibration) free software and also provides no support on that score. Trotec If the device is used in heavily contaminated environments, the accepts no liability concerning the use of this free software and sensor must be cleaned with the supplied zero filter.
For further return options provided by us please Cleaning refer to our website https://de.trotec.com/shop/. Clean the device with a soft, damp and lint-free cloth. Make The separate collection of waste electrical and electronic sure that no moisture enters the housing. Do not use any...