Turnigy REAKTOR / iCharger 206b Calibration

Turnigy REAKTOR / iCharger 206b Calibration

Advertisement

Turnigy REAKTOR / iCharger 206b calibrating:
First measure the voltages with a multimeter.
Vi = Voltage input / power source output where charger will be connected
Vo = Voltage output on the lipo on it's discharge plug
C1 = Voltage of lipo cell 1
C2 = Voltage of lipo cell 2
C3 = Voltage of lipo cell 3 4 5 6
Power-up the charger: Press and hold all 4 buttons at startup until you here 3
beeps
Press and hold "stop" button for 3 seconds until beep
- Make sure you have connected your lipo (charge and balance plug) at this
moment
Press and hold 3 buttons (Dec / Inc / Start-Enter) until you here a beep
Now set Vi at desired value with the < > buttons, when done press Start-Enter
Now set Vo at desired value with the < > buttons, press Start-Enter when done
Optional: You can also set Internal and External temperature at this point, and if you
press and hold Start-Enter for 3 seconds it will go to internal-resistance mode
Press "stop"
Press "Inc" to go to cell voltages
Press and hold 3 buttons (Dec / Inc / Start-Enter) until you here a beep
Now set C1 at desired voltage value with the < > buttons, when done press Start-
Enter and set all other cell voltages
Press "stop" twice to exit when done!
Video guide:
http://www.youtube.com/watch?v=bEpEN6piv8s
Next page for print / write down:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the REAKTOR / iCharger 206b and is the answer not in the manual?

Questions and answers

Summary of Contents for Turnigy REAKTOR / iCharger 206b

  • Page 1 Turnigy REAKTOR / iCharger 206b calibrating: First measure the voltages with a multimeter. Vi = Voltage input / power source output where charger will be connected Vo = Voltage output on the lipo on it's discharge plug C1 = Voltage of lipo cell 1...
  • Page 2 Vi = Vo = C1 = C2 = C3 = C4 = C5 = C6 =...

This manual is also suitable for:

9466000001-0

Table of Contents