Check Burners; Check Surface Burners; Finalize Installation; When All Hookups Are Completed - GE CAFE CGY366 Installation Instructions Manual

36” all gas professional ranges
Table of Contents

Advertisement

Available languages

Available languages

10

CHECK BURNERS

WARNING
A. Burners - Place surface burners into corresponding
positions on cooktop.
B. Caps - Place caps on proper size burner.
C. Grates - The left and right grates are
interchangeable. Place the grates on the cooktop.
Burner Cap Properly Seated
Burner Cap Not Properly Seated
11

CHECK SURFACE BURNERS

Push and turn a knob to the LITE position. A clicking
sound indicates proper operation of the ignition
knob out of the LITE position. Try each burner in
succession until all burners have been checked.
Quality of Flames
Determine the quality of flames visually. Normal
burner flames should look like (A) or (B).
heated or signs of flickering orange due to particles in
the gas or air.
31-2000814 Rev. 1
Installation
(A) Soft blue flames—
Normal for natural gas
(B) Yellow tips on
outer cones—
Normal for propane (LP) gas

FINALIZE INSTALLATION

Place the burner grates over the burners. The grates
should be seated and should not rock.
WHEN ALL HOOKUPS ARE
COMPLETED
Make sure all controls are left in the off position. Make
range is unobstructed.
Check that all packing materials and tape have been
remove these materials could result in damage to the
appliance once the appliance has been turned on and
surfaces have heated.
13