Table of contents: Introduction General description 1.1 Options Technical data and dimensions 2.1 Specifi cations power supply 2.2 Overall searchlight dimensions & electrical cable dimensions 2.3 Cut/out main/slave panel 2.4 Overall dimensions Power supply Direction for use 3.1 Parameter setting for xbo HTP OFR 3.2 Program menu - Parameter setting 3.3 Operation modes 3.4 Program menu - Parameter mode setting...
This commitment to quality and expertise provides the foundation for Norselight to be possibly the world’s leading supplier of maritime lighting. However, in order to stay in front, Norselight would very much appreciate all comments that you may have regarding our quality products or services.
1.0 General description: Searchlight The R5 searchlights XS 1000 and XS 2000, are made from seawater resistant aluminium, welded and fi nished with white powder coat.The forks are made of stainless steel - The lamp housing contains one lamp, ignitor, silverplated glass-refl ector, hardened frontglass, noise fi...
2.0 Technical data and dimensions General specifi cations searchlight unit: Technical spec. for all XS models IP Classifi cation Maximum ambient temperature 50ºC Minimum ambient temperature -40ºC Horizontal movement 360º Vertical movement +-27,5º Inclination speed V/H ≤ 4°/s Colour RAL 9016 Forks Stainless steel Article no.
2.1 Technical data and dimensions Specifi cations Power supply: NP-0725 500-1000W Art No. 1009158 IP classifi cation IP20 Temperature ambient -30°...50°C Input Voltage 90-264VAC; single phase Dimensions ABH 180 x 254 x 82,5mm Weight 3,35kg NP-0725 500-1000W with heat sink Art No.
2.2 Overall searchlight dimensions & electrical cable dimensions XS 1000-2000: ← Front of motorhouse ← Common for all R5 models. XS 1000 Entry / Description Cable gland Blind plug Blind plug Cable Ø min / max 6-13mm 6-13mm 115 V AC Cable entry 230 V AC XS 2000...
2.4 Overall dimensions Power supply For 500-1000W NP-0725 (for mounting in the motor-house) This single-phase rectifi er has been designed to ensure correct operation and long life to short arc Xenon lamps up to 1000W. It is characterized by galvanic insulation, a soft inrush current, alow residual ripple value and a stable output current.
Page 12
For 500-1000W NP-0725 with heat sink (for mounting in the motor-house) ouse) This single-phase rectifi er has been designed for higher temperature ensure correct operation and long life to short arc Xenon lamps up to 1000W. It is characterized by galvanic insulation, a soft inrush current, alow residual ripple value and a sta- ble output current.
Page 13
PX-50N for 1000W These extremely compact rectifi ers for single-phase inputs have been designed to feed 1000W Xenon lamps, meeting the requirements of lamps manufacturers to ensure correct operation and long life of the lamp. The units are fi tted with a transformer with taps for output lamp power regulation and a special circuit to avoid the lamp turn off...
Page 14
For 1600-2000W N3-80E These high quality rectifi er power supplies have been expressly designed to ensure the correct operation and long life of short arc Xenon lamps. These units, developed to meet the recommendations of Xenon lamp manufacturers, are fi tted with special IREM transformers with adjustable magnetic shunt for continuous output regulation over the entire operating range.
Page 15
For 1000-3000W EX-100 D/1 This electronic power supply for single phase or double phase 230Vac 50/60Hz input has been designed to feed from 1000W to 3000W short arc Xenon lamps, meeting all the requirements of lamp manufacturers to ensure correct operation, long life to the lamp, and high reliability. Weight 19,5kg Further instructions in Installation guide for Rectifi...
3.0 Directions for use Parameter setting for xbo HTP OFR (only for: EX-100 D/1 with factory settings) Lamp (operating range: 1000 and 2000W): max: power of the lamp. When entered, an automatic control will avoid exceeding this value. Factory setting: is on 1000W. Lamp (operating range: 55A - 85A): max.
3.3 Operation modes The tree operation modes can be used alternately but not all at the same time. Act on the keys of the synoptic panel to shift from one mode to the other. The default mode is: manual mode from synoptic panel. When the RS232 serial line is ON, the operating parameters will be sent through this line.
4.0 Electric installation Note: Disconnect the power when working on the equipment! Electrical equipment must be installed by authorized personnel! Check the polarity when connecting 24V DC! All searchlight system equipment MUST BE connected to ground/earth! The main operation panel requires 24V DC connected in series with a 3A slow fuse to the positive (+) conductor.
5.0 Maintenance The guarantee is only valid against production faults. It do not cover damage caused by transportation, damage due to disregard of this technical Manual or adverse external eff ects. Guarantee regarding the bulb, please look at the guarantee papers following the bulb. This must be fi...
5.1 Spare Parts List Pos Spare part XS1000 XS2000 Front ring complete 1009169 1009149 Lamp Xenon - up to series no. 402028 1009699 Lamp Xenon - from series no. 402029 1006207 Lamp Xenon - up to series no. 402018 1009700 Lamp Xenon - from series no.
5.2 Lamp replacement 1. Turn off the fuse to the power-supply/rectifi er and make sure nobody can turn it on during the replacement of the lamp. Allow the lamp to cool down. Use safety equipment. Face cover and Gloves and are a minimum. Caution! Because of its high internal pressure, there is a risk that this lamp will explode in either the hot or cold state.
Page 35
8. Unscrew the lamp using hand force. 9. Replace the lamp, tighten by hand force. 10. Put back the positive connector Must be pushed in as far as possible, and the bolt tightened fi rmly. 11. Put back the lamp holder bracket 12.
Page 36
14. Safety During operation it emits intense UV radiation which is harmful to the eyes and skin. Keep light beam and hot components away from from fl ammable materials! 15. Disposal Read attached operating instruction for the lamp...
5.3 Troubleshooting Searchlight don ’t move , horizontal or vertical: Check that there is no obstructions eg. stucked cable . Open the lid on motor house and check the red warning lamps on the PCB. If the light is red (and the searchlight is not in end position) on one of the lamps it can be caused by the actual motor or the gear.
6.0 Warranty The warranty does not cover damage due to disregard of specifi ed operating parameters. Claimhandling: Contact your Customer service offi ce, see page 4. The lamp must be sent back in its original box together with the guarantee card. The Supplier shall in a period of two (2) year following the date on which the risk in the Products passed to the Purchaser, be liable for defects in the delivered Products.
Page 39
GLAMOX Production GmbH & Co. KG XS_R5 Xen Doc.:7SL5002001 Rev:16 DCN:23339 Date:2020-03-24 Glasower Weg 5, 17166 Teterow, Germany, www.glamox.com/gmo...