D) Installing Drain Pan; E) Shelf Clips For Door Models; F) Cord & Plug; G) Power Supply - Traulsen centerline CLUC-27R-SD Owner's Manual

Undercounter refrigerators & freezers
Table of Contents

Advertisement

III. d - INSTALLING DRAIN PAN
Centerline compact models are shipped with the drain pan
wrapped up and stored inside the unit.
Remove the drain pan and slide it on the rails underneath the
cabinet. Route the drain tubing drain into the pan to ensure
water drains into the pan (see figure 2).
III. e - SHELF CLIPS FOR DOOR MODELS
Shelves and shelf clips are shipped with the unit. Shelves
are mounted on pilasters using clips to adjust the shelf
height. For each shelf, insert four (4) shelf clips into the
pilaster slots at the same height. The shelf clips have a
small projection on top which holds the shelf in position and
prevents it from slipping forward. To remove the clips, pinch
down on the mounting side and pull them outwards. Make
sure the clips are securely installed. Lastly, set the shelf into
its new position.
Fig. 3
III. INSTALLATION (continued)
Fig. 2
III. f - CORD & PLUG
All Centerline compact models are supplied with a cord &
plug attached. It is shipped coiled and secured by a nylon
strip to the back of the cabinet near condensing unit area.
For your safety and protection, all units supplied with a cord
and plug include a special three-prong grounding plug on
the service cord. Select only a dedicated electrical outlet
with grounding plug for power source.
NOTE: DO NOT UNDER ANY CIRCUMSTANCES CUT OR
REMOVE THE ROUND GROUNDING PRONG FROM THE
PLUG OR USE AN EXTENSION CORD.
III. g - POWER SUPPLY
The supply voltage should be checked prior to connection
to be certain that proper voltage for the cabinet wiring
is available (refer to the serial tag to determine correct
unit voltage). Make connections in accordance with local
electrical codes. Use qualified electricians.
Use of a separate, dedicated circuit is required. Size wiring
to handle indicated load and provide necessary over current
protector in circuit (see amperage requirements on the unit's
serial tag).
III. h - CLEARANCE
In order to assure optimum performance, the condensing
unit of your Centerline unit MUST have an adequate supply
of air for cooling purposes. Therefore, the operating location
must have a minimum of 1" clearance on top of the unit for
proper air flow. There are no clearance requirements for
the sides or rear.
-3-