RAYLASE SUPERSCAN II Manual page 26

2-axis laser beam deflection units
Table of Contents

Advertisement

Mirrors & Objectives
Scan mirrors and objectives with optimized mounts are available for all typical laser types, wavelengths, power densities, focal
lengths and working fields. Customer specific configurations are also possible. Please contact the RAYLASE support team for
specific information and possible combinations on +49-8153-8898-0 or email
Options
The SUPERSCAN II scan heads provide two types of water-tempering connections for the electronics and galvanometer
scanners, Straight [W] connectors and 90° [W2] connectors along with air-cooling [A] of the deflection mirrors. This ensures
constant working conditions and excellent long-term stability, thus guaranteeing reliable operation even in high-laser-power
applications.
Auto calibration option [K] available for all SUPERSCAN II models with reference sensors for automatic drift compensation
which ensures process stability.
BE and SC mirrors allow for higher speed performance due to the lightweight mirror substrates and optimized mirror mounts.
Air flushing Specifications
Specifications
Air
Water Tempering Specifications
Specifications
1)
Water
Temperature
Pressure
(1) Caution: When using cooling water including deionized water, suitable additives must be used to prevent the growth of
algae and protect the aluminium parts against corrosion.
Additive recommendations: Standard industrial applications e.g. CCL105 (NALCO)
Food & beverage, packaging applications: e.g. polypropylene glycol e.g. DOWCAL N. (Dow Chemical).
Please consult your additive supplier for dosage information
03/2014
Clean air free of water & oil
Clean tap water with additives
22-28°C
2-5 bar
support@raylase.de
Flow rate
100 l / min
Flow rate
2 l / min
4 l / min
6 l / min
Air Pressure
1.0 - 1.5 bar
Pressure loss
0.3 bar
0.4 bar
0.7 bar
SUPERSCAN-IIE