PCB interface and dip switch settings
The PCB interface and dip switch settings
must only be changed by a licensed gasfitter.
They have been provided as there may be
a requirement to change the temperature of
the water delivered from the water heater
of change the dip switch settings if fitting a
sideways flue diverter.
Care must be taken when changing the
temperature or dip switch settings as
WARNING
they can be easily switched or bumped
into the wrong position. Fully check the
operation of the water heater before
leaving including the temperature of the
water delivered.
The cover of the water heater will need to be
removed to carry out this operation. As this
will expose live mains voltage wiring please
disconnect the power supply before
removing the front cover.
We wish to draw your attention to the
requirements of the New Zealand Building
Code and compliance document G12. This
requires that water delivered to sanitary
fixtures be no more than 55 °C. Increasing the
water heater set temperature will require that
you protect all sanitary fixtures to which the
appliance is plumbed with suitable tempering
valves or something similar.
Rinnai will accept no liability for issues arising
out of the use of this information.
Communication interface socket
Data transfer button for PCB replacement - push button 1 (PB1)
Data transfer LED, illuminates to show data transfer in progress
PB1
PB2
MODE button, places the PCB into programming mode (PB2)
MENU button, cycles through available modes (PB3)
PB3
Forced combustion rate setting mode, raises the gas pressure
VALUE button, cycles through available values (PB4)
PB4
Forced combustion rate setting mode, lowers the gas pressure
PB5
Forced high/low selection button, (PB5)
LED digital display, displays menu, value and forced high/low status
8
Dip switch (factory default all switches are in the off position)
SW1
SW1 and SW3 are only set to ON when a sideways flue diverter is fitted,
SW2
otherwise they MUST remain set in the OFF position.
SW3
SW4
SW2 and SW4 are not used and MUST remain set in the OFF position.
16 | Rinnai INFINITY EF26 and A-Series installation guide 01-20
If you have any doubts about the performance
of the water heater, please contact Rinnai by
phoning 0800 RINNAI (0800 746 624).
The following information details settings for
the Rinnai INFINITY EF26 and A-Series models
only. They are not applicable for other models.
Basic operation of the PCB interface
To place the PCB into programming mode
press PB2 until the LED digital display
shows 1, noting that the current set value
will be displayed shortly afterwards.
To alter a value press PB4, each press
of the button will select the next available
value.
To change to another menu, press PB3,
each press of the button will select the next
available menu.
To exit the programming mode and save the
selected settings press PB2 until the LED
display goes blank.
Note:
If no buttons are pressed the PCB will
automatically exit programming mode after
10 mins.
Exiting programming mode sets the value
last viewed as the current value.
EF26 error code 92
Neutraliser alert will flash when the
total calorific value reaches 255 GJ,
approximately 16 years of residential
use. Water heater can still work, but the
condensate trap should be changed.
To cancel the error code, press PB4
and PB5 together and hold for more
than five seconds.