Acer V50LA User Manual page 23

Acer v50la motherboards: user guide
Hide thumbs Also See for V50LA:
Table of Contents

Advertisement

Table 1-5
System Error Messages (continued)
Message
Memory Error at:
MMMM:SSSS:OOO
(W:XXXX, R:YYYY)
where:
M: MB, S: Segment,
O: Offset, X/Y: write/read
pattern
CPU Clock Mismatch
Onboard Serial Port 1
Conflict
Onboard Serial Port 2
Conflict
Onboard Parallel Port Conflict
Pointing Device Error
Pointing Device Interface
Error
Press
key to continue or
+
+
for Setup
Real Time Clock Error
System Board
Action
Check SIMMs on the system
board. Contact your dealer.
Run Setup. Check if the CPU
clock is correct. If correct, exit
Setup and reboot the system.
If the error message reappears,
ask for technical assistance.
Run Setup and disable the
port.
Run Setup and disable the
port.
Run Setup and disable the
port.
Check and connect pointing
device.
Replace the pointing device or
contact your dealer.
Press
or
+
+
to enter
Setup.
Check the RTC chip. If it is still
good, run Setup. If not, replace
the RTC chip.
1-23

Hide quick links:

Advertisement

Table of Contents
loading