GL Sciences GL-Tip SDB Instruction Manual

Advertisement

Thank you for purchasing GL-Tip™ SDB. GL-Tip SDB is a sample preparation tip column packed with styrene di vinyl
benzene polymer designed for desalting and enriching peptide samples, particularly hydrophobic phosphopeptides.
GL-Tip™ SDB is often used in combination with GL-Tip™ GC (available separately, P/N
peptides with the widest range of polarity are captured in high yields.

1. Product Description

○ Check for damage or missing parts.
Part No. (Order No.)
GL-Tip SDB
Instruction Manual

2. Product Handling

○ Handle GL-Tips delicately; avoid dropping or tapping the tips, which may harm the column bed.
○ Do not autoclave GL-Tips
○ GL-Tips are designed for use with a centrifuge. Attempting to use GL-Tips with syringes, pipettes, or
any air-forced solvent flow methods may result in reduced or irreproducible results.
○ Actual maximum or minimum sample concentration and loading volume are sample-dependent, and can vary with
different detergents or denaturants present in the sample. Therefore, sample loading conditions optimum –for –your
–particular -sample must be determined empirically in your laboratory.
○ Make sure to use the purest acetonitrile available. Even some HPLC-grade acetonitrile has been shown to contain
both high and low MW impurities which could complicate MS results.
○ GL-Tip SDB are disposable and should not be reused.
○ GL-Tip SDB should be stored in an environment with relatively constant temperature and humidity.

3. Solvent / Solution Preparation*

① Recommended Chemicals
・Highly pure acetonitrile (HPLC grade or higher)
・Trifluoroacetic acid (HPLC grade or higher)
② Solutions Required
・Solution A: Water (0.1% TFA) or 5% acetonitrile aqueous solution (0.1% TFA)
・Solution B: 80% acetonitrile aqueous solution(0.1%TFA)
*Note: Prepare solutions A & B on the day of the experiment
Japan: 6-22-1 Nishishinjuku, Shinjuku, Tokyo, 163-1130, Japan Tel. +81-3-5323-6620, Fax. +81-3-5323-6621
USA: 4733 Torrance Blvd, Suite 255, Torrance, CA 90503 Tel. (310)265-4424, FAX (310)265-4425,
GL-Tip™ SDB Instruction Manual
Contents
7820-11201)
7820-11200
96 tips
1
www.glsciences.com
www.glsciencesinc.com
email: info@glsciencesinc.com
to ensure that
email: world@gls.co.jp

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GL-Tip SDB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GL Sciences GL-Tip SDB

  • Page 1 GL-Tip™ SDB Instruction Manual Thank you for purchasing GL-Tip™ SDB. GL-Tip SDB is a sample preparation tip column packed with styrene di vinyl benzene polymer designed for desalting and enriching peptide samples, particularly hydrophobic phosphopeptides. GL-Tip™ SDB is often used in combination with GL-Tip™ GC (available separately, P/N...
  • Page 2 - Add at least 50 uL of Solution B and centrifuge (3,000 x g, 3min, RT) Peptides GL-Tip SDB is manufactured, inspected, packed and shipped under strict standards of quality control. Please contact us if you have questions regarding the proper use and performance of GL-Tips.

This manual is also suitable for:

7820-11200

Table of Contents