Technical Parameters; General Parameters; Electrical Parameters; Transmitting Current - Ebyte LoRa SX-1276 1W User Manual

Table of Contents

Advertisement

1. Technical parameters

1.1 General parameters

Model No.
LoRa SX-1276
SX1276
1W module

1.2 Electrical parameters

1.2.1 Transmitting current

Model No.
LoRa
SX-1276
1W
module

1.2.2 Receiving current

Model No.
LoRa SX-1276 1W
module

1.2.3 Turn-off current

Model No.
LoRa SX-1276 1W
module

1.2.4 Supply voltage

Model No.
Copyright ©2012–2017,Chengdu Ebyte Electronic Technology Co.,Ltd
IC
Size
25.0*40.0 mm
Min
Typ
570.4
620.0
682.0
Min
Typ
21.2
23.0
Min
Typ
1.5
3.0
Min
Typ
Net WT
Operating temp.
5.2±0.1g
-40 ~ 85℃
Max
Unit
● When designing current supply circuit, 30% margin is
recommended to be remained so as to ensure long-term
stable operation of the whole module;
● The current at the instant of transmitting may be high,
but the total energy consumed may be lower due to very
mA
short transmitting time;
● When using external antenna, the impedance matching
degree at different frequency points between antenna
and module may affect the transmitting current value at
different levels.
Max
Unit
● The current consumed when the RF chip is only working
at receiving mode is called as receiving current,the
tested receiving current may be higher for some RF chips
with communication protocol or the developers have
25.3
mA
loaded their own protocol to the whole module.
● The current at pure receiving mode will be mA level, the
users have to realize µA level receiving current through
firmware development.
Max
Unit
The turn-off current means the current consumed when
CPU, RAM, Clock and some registers remain operating while
SoC is at very low power consumption status.
4.5
µA
● The turn-off current is always lower than the current
consumed when the power supply source of the whole
module is at no-load status.
Max
Unit
Operating humidity
Storage temp.
10% ~ 90%
Remark
Remark
Remark
Remark
-40 ~ 125°C