(3) Set the signal generator as follows :
Signal generator setting
FREQUENCY (carrier frequency) :
CE38 model ; 618.000 MHz
U30 model ; 578.125 MHz
U42 model ; 650.125 MHz
RF OUTPUT (Output level) : 60 dBuV
MODULATION (Modulation frequency) : 1 kHz
DEVIATION (Frequency deviation)
(4) Check that RF Indicator LED lights (green) and "NO
TONE" message appears on LCD (Tuner [1]).
(5) Change the RF OUTPUT (output level) of the signal
generator as shown below.
RF OUTPUT (output level) : 15 dBuV
(6) Check that RF Indicator LED goes off (green) and "NO
TONE" message disappears on LCD (Tuner [1]).
(7) Increase gradually the RF OUTPUT (output level) of
the signal generator. Check that RF OUTPUT (output
± 5 dB at when RF Indicator lights
level) is 25 dBuV
EMF
(green LED) and "NO TONE" message appears on
LCD (Tuner [1]).
RF indicator lights.
(8) Connect the signal generator to the ANTENNA B IN
connector with DC cut fixture, and perform the proce-
dures (3) through (7) above.
(9) Set the channel setting (Tuner [1]) and FREQUENCY
(carrier frequency) of the signal generator as shown 1
and 2 below.
Perform the procedures (1) to (8) above, for each
channel setting (1 and 2).
1 Channel setting :
CE38 model ; Group 00, 3801 channel (606.125 MHz)
U30 model ; Group 00, 3001 channel (566.125 MHz)
U42 model ; Group 00, 4201 channel (638.125 MHz)
Signal generator setting :
FREQUENCY (carrier frequency)
CE38 model ; 606.125 MHz
U30 model ; 566.125 MHz
U42 model ; 638.125 MHz
2 Channel setting :
CE38 model ; Group 00, 4063 channel (629.875 MHz)
U30 model ; Group 00, 3347 channel (589.875 MHz)
U42 model ; Group 00, 4547 channel (661.875 MHz)
Signal generator setting :
FREQUENCY (carrier frequency) :
CE38 model ; 629.875 MHz
U30 model ; 589.875 MHz
U42 model ; 661.875 MHz
2-12
(= _53 dBm)
EMF
: ± 5 kHz
(= _98 dBm)
EMF
AF
RF
8. BATT (Battery) Indicator Check
Procedure
n
The checking procedures describe that the WRU-806B (to be
adjusted) is installed into the Tuner [1] slot on the MB-X6.
(1) Set the MB-X6 as follows :
WRU-806B Front panel (Tuner [1])
Channel setting :
CE38 model ; Group 00, 3932 channel (618.000 MHz)
U30 model ; Group 00, 3201 channel (578.125 MHz)
U42 model ; Group 00, 4401 channel (650.125 MHz)
Muting : ON (Normal mode)
Rear panel
ATT (ANTENNA A, B) switch : 0 dB
(2) Connect the signal generator to the ANTENNA A IN
connector with DC cut fixture.
(3) Set the signal generator as follows :
Signal generator setting
FREQUENCY (carrier frequency) :
CE38 model ; 618.000 MHz
U30 model ; 578.125 MHz
U42 model ; 650.125 MHz
RF OUTPUT (Output level) : 60 dBuV
MODULATION (Modulation frequency) : 32.782 kHz
(32.782 kHz must be set by connecting Function generator)
DEVIATION (Frequency deviation)
(4) Turn on and off the MODULATION (modulation fre-
quency) of the signal generator as follows, and check that
BATT Indicator (Tuner [1]) change also as follows :
MODULATION setting BATT indicator of Tuner [1]
of signal generator
ON
BATT indicator (LCD) ;
Turn the signal
generator on and BATT
indicator starts blinking
after 30 seconds.
BATT indicator (LED) ;
Turn the signal
generator on and BATT
indicator starts blinking
after 30 seconds.
OFF
BATT indicator (LCD) ;
Goes out.
BATT indicator (LED) ;
Goes out.
(5) Connect the signal generator to the ANTENNA B IN
connector with DC cut fixture, and perform the proce-
dures (3) and (4) above.
(= _53 dBm)
EMF
: ± 2.1 kHz