FEATURES
1. ON/OFF Reset Control Switch and Circuit Breaker
Controls power to all outlets. The switch is also a 15 A breaker.
When an overload occurs, it will automatically switch o .
To resume operation, ensure the overload condition is
removed and reset the surge protector by switching the unit ON.
2. Ground Indicator LED
Illuminated when the ground protection feature is
working properly.
3. Surge Protected Indicator
Illuminated when the surge protection feature is
working properly.
4. Standard Grounded Outlets (4) and Transformer-spaced
2
Grounded Outlets (4) with Safety Covers
Slide the plastic outlet cover over outlets that are not used.
3
This ensures the safety of children and prevents potential electric
shocks and damage caused by highly dusty environments.
5. Surge Protected Data Line Connections
Protect your equipment from surge along phone lines.
A. Connect the phone line from wall outlet to the "In" port.
B. Connect the phone lines to the "Out" ports.
6. Surge Protected Cable and Satellite Connections
Protect coaxial lines from surges and spikes.
SPECIFICATIONS
• Model Number: HT806TCRC1 / HT812TC
• Outlets: Standard Grounded Outlets (4) and
Transformer-spaced Grounded Outlets (4)
• Power Cord Length: 6 ft / 12 ft
• Plug Type: Low-Profile Right-Angle Plug
• Surge Protection: 4,350 Joules
4
• Electrical Rating: 125 V/15 A/1875 W
• UL Clamping Voltage: UL 1449 4th/500 V (H-N, H-G, N-G)
• Maximum Peak Current: 150,000 A
• 3 AC Lines Protected: H-N: 90,000 A, H-G: 30,000 A, N-G:
30,000 A (The maximum surge possible on household wiring
is 6,000 volts)
• Response Time: Less than 1 nanosecond
• Attenuation: Up to 58 dB
• Telecommunications Protection: RJ11 1 in/2 out
• Coaxial Communications Protection: Cable (Coaxial) 1 pair
• EMI/RFI Filtration: 150 kHz to 100 MHz
• Circuit Breaker: Resettable 15 Amp
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK - Use only in dry
locations and only indoors. DO NOT plug into another relocatable
power tap. DO NOT "daisy chain" surge protectors. DO NOT use
with any aquarium equipment. DO NOT use if properly grounded
outlets are not available. DO NOT install this device if there is less
than 10 meters (30 feet) or more of wire between the electrical
outlet and electrical service panel. DO NOT use for medical or life
support equipment. This device features an internal protection that
will disconnect the surge protective component at the end of its
useful life, but it will maintain unprotected power to the load.
TROUBLESHOOTING
▪ If the ON/OFF is switched OFF, the 15 Amp circuit breaker may
have tripped. Examine your connected equipment and remove
the device that is overloading the circuit. Then, turn the
ON/OFF switch back to RESET.
▪ If the grounded indicator does not light when you plug in the
surge protector, move the surge protector to a di erent
grounded three-prong AC outlet. If it still does not light, return
the product to the retailer for assistance. If the surge protector
appears to be working properly, your outlets may not be
properly grounded and need to be repaired by a professional
electrician. If the grounded indicator turns o after a period
of use, the surge protection has been depleted. Replace your
surge protector.
▪ If the protected indicator does not light, the surge protector's
AC lines are no longer protected from surge. The surge
protector may have received a power surge or spike beyond
its specified limits that overloaded the protection circuitry and
rendered it inactive. The surge protector has protected your
connected equipment as designed, but it will not protect
against future surges, and spikes. It should be replaced.
TECHNICAL SUPPORT
Please contact our Tech Support Department
with installation, troubleshooting, or general
product questions.
• Phone: 1-877-297-6937
• Email: tech@cpsww.com
• Hours of Operation:
Monday – Friday 7:00am – 6:00pm CST
1
2

Advertisement

loading

Summary of Contents for CyberPower HT806TCRC1

  • Page 1 DO NOT plug into another relocatable power tap. DO NOT “daisy chain” surge protectors. DO NOT use of the HT806TCRC1/HT812TC. Please take a few moments to read this manual. with any aquarium equipment. DO NOT use if properly grounded outlets are not available.
  • Page 2 Any such installation voids description of the damage to your connected equipment. the warranty. 4. Pack and ship the product to CyberPower and the item(s) 3. The product and connected equipment must have been of connected equipment, a repair cost estimate for the...

This manual is also suitable for:

Ht812tc