TFT Ultimatic ER Manual

TFT Ultimatic ER Manual

Monitor nozzles

Advertisement

Quick Links

INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE
WARNING
This instruction manual is intended to familiarize fi refi ghters and maintenance personnel with the operation, servicing
and safety procedures associated with the nozzle. This manual should be kept available to all operating and maintenance
personnel.
TASK FORCE TIPS LLC
MADE IN USA • tft.com
©Copyright Task Force Tips LLC 2012-2019
Read instruction manual before use. Operation of this device without understanding the manual
and receiving proper training is a misuse of this equipment. A person who has not read and
understood all operating and safety instructions is not qualifi ed to operate the Ultimatic ER
Nozzle. Call 800-348-2686 with any questions.
MANUAL:
Ultimatic ER Monitor Nozzles
3701 Innovation Way, Valparaiso, IN 46383-9327 USA
800-348-2686 • 219-462-6161 • Fax 219-464-7155
LIB-065 August 30, 2019 Rev 01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultimatic ER and is the answer not in the manual?

Questions and answers

Summary of Contents for TFT Ultimatic ER

  • Page 1 WARNING and receiving proper training is a misuse of this equipment. A person who has not read and understood all operating and safety instructions is not qualifi ed to operate the Ultimatic ER Nozzle. Call 800-348-2686 with any questions. This instruction manual is intended to familiarize fi refi ghters and maintenance personnel with the operation, servicing and safety procedures associated with the nozzle.
  • Page 2: Table Of Contents

    INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE Understand manual before use. Operation of this device without understanding the manual and DANGER PERSONAL RESPONSIBILITY CODE receiving proper training is a misuse of this equipment. Obtain safety information at www.tft. com/serial-number SECTION 3.0 SECTION 4.9...
  • Page 3: Meaning Of Signal Words

    2.0 GENERAL INFORMATION The Task Force Tips Ultimatic ER nozzles are designed to provide excellent performance under most fi refi ghting conditions. Their rugged construction is compatible with the use of fresh water (see section 2.5 for saltwater use). Other important operating features are: •...
  • Page 4: Models And Terms

    MADE IN U.S.A. 40-500 LPM @ 6.8 BAR information at www.tft.com/serial-number VALPARAISO, IN 46383-9327 • +1 219 462-6161 • 800 348-2686 www.tft.com www.tft.com B-TO-ERP WITH 6-PIN PLUG FOR TFT MONITORS Figure 2.1 Models and Terms 2.2 MECHANICAL SPECIFICATIONS Weight 6.4 lbs 2.9 kg...
  • Page 5: Nozzle Couplings

    3.0 FLOW CHARACTERISTICS Each Ultimatic ER nozzle has a pressure rating on the face of the baffl e which can be seen by looking at the front end of the nozzle. Make sure that the pump system that is being used is capable of the fl ows and pressures of the selected Ultimatic ER Model.
  • Page 6: Trajectory Charts

    3.1 TRAJECTORY CHARTS 75 PSI ELECTRIC INLET CURVE FLOW PRESSURE REACTION REMOTE CONTROL NOZZLE KGF/CM INLET CURVE FLOW PRESSURE REACTION HORIZONTAL DISTANCE (FEET) INLET 100 PSI ELECTRIC CURVE FLOW PRESSURE REACTION REMOTE CONTROL NOZZLE KGF/CM INLET CURVE FLOW PRESSURE REACTION 10.4 16.3 HORIZONTAL DISTANCE (FEET)
  • Page 7 INLET 120 PSI ELECTRIC CURVE FLOW REACTION PRESSURE REMOTE CONTROL NOZZLE KGF/CM INLET CURVE FLOW PRESSURE REACTION 12.2 19.0 HORIZONTAL DISTANCE (FEET) 26.8 34.0 INLET 150 PSI ELECTRIC CURVE FLOW PRESSURE REACTION REMOTE CONTROL NOZZLE KGF/CM INLET CURVE FLOW PRESSURE REACTION 14.0 10.6...
  • Page 8: Pattern And Flush Control

    4.1 PATTERN CONTROL TFT’s nozzles have full pattern control from straight stream to wide fog. The pattern can be adjusted using the linear actuator either by electronic control or by twisting the KNOB in either direction. The STREAM SHAPER moving forward transitions the STREAM SHAPER to the straight stream position.
  • Page 9: Drawing And Parts List

    6.0 DRAWING AND PARTS LIST 18 17 16 15 10 9 INDEX DESCRIPTION QTY. PART NUMBER INDEX DESCRIPTION QTY. PART NUMBER SHAPER WITH BUMPER B500 O-RING-030 VO-030 1/8" NYLON BALL V2135 VALVE PLUG B590 QUAD-RING-225 VOQ-4225 O-RING-109 VO-109 SMALLEY RING V4280 I/O SCREW B595...
  • Page 10: Warranty

    TFT, at 3701 Innovation Way, Valparaiso, Indiana 46383-9327 USA, within a reasonable time after discovery of the defect. TFT will examine the equipment. If TFT determines that there is a defect attributable to it, TFT will correct the problem within a reasonable time.
  • Page 11: Flow Testing

    Repair parts and service procedures are available for those wishing to perform their own repairs. Task Force Tips assumes no liability for damage to equipment or injury to personnel that is a result of user service. Contact the factory or visit the web site at www.tft.com for parts lists, exploded views, test procedures and troubleshooting guides.
  • Page 12: Inspection Checklist

    Operating a nozzle that fails any of the above inspections is a misuse of this equipment. TASK FORCE TIPS LLC 3701 Innovation Way, Valparaiso, IN 46383-9327 USA 800-348-2686 • 219-462-6161 • Fax 219-464-7155 MADE IN USA • tft.com ©Copyright Task Force Tips LLC 2012-2019 LIB-065 August 30, 2019 Rev 01...

Table of Contents