Operating Instructions - TRAMEX Moisture Encounter Plus User Manual

Hide thumbs Also See for Moisture Encounter Plus:
Table of Contents

Advertisement

Find Quality Products Online at:
Moisture Encounter Plus
User Guide

Operating Instructions

The instrument face with brief notes on the push button controls
and LED indicators is shown below.
1. Press the ON button to power up. The LED for the last used
scale will light. [Note – If the battery voltage is getting low,
the three LEDs will flash sequentially for a short period. The
instrument will continue to operate for some time but it is
recommended that the PP3 (9 volt) battery be changed as
soon as convenient.]
2. To change scale, press/release the SCALE button until the
LED opposite the required scale lights.
3. Hold your Moisture Encounter Plus directly on the
material being tested ensuring both conductive rubber
electrodes are fully in contact with the surface.
4. For wood or wood products read the moisture content from
the upper line (Wood) of the meter dial which is marked from
5% to 30%. Audio signal will sound when meter indicates
high reading.
5. To turn audio signal on or off, press ON button twice in quick
succession.