Table of Contents

Advertisement

Quick Links

DV51 DV51CH
Instruction Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Adroit DV51 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Airflow Adroit DV51

  • Page 1 DV51 DV51CH Instruction Manual...
  • Page 2: Table Of Contents

    Adroit DV51 / Adroit DV51CH . . . . . . . . . . . . . . . . . .
  • Page 3: Safety

    DISPOSAL OF THE VENTILATION UNIT Do not dispose of electronic devices with household waste . Follow local laws and regulations on safe and ecological disposal of the product . © Airflow - We reserve the right to make changes without prior notice...
  • Page 4: Safety Signs Used In The Instructions

    ► Network router . In this case the Adroit unit can be controlled via your laptop, 4. Double click on the Airflow icon. tablet, smartphone etc using a 5. Now you are connected to the Adroit Home service, you are able network created by the router .
  • Page 5: Ventilation Unit Control

    The mode is primarily used to create a short period reduces the risk of of overpressure in the dwelling, stopping spillage of moisture damage . smoke back into the property . © Airflow - We reserve the right to make changes without prior notice...
  • Page 6: Adroit Dv51Ch

    DV51 DV51CH Adroit DV51CH CAUTION • Neglecting the The Adroit DV51CH ventilation unit is controlled by using the cleaning of the grease Adroit cooker hood that is connected to the unit . The cooker filter can cause a fire hood is designed to be used above the cooker top, as a general hazard .
  • Page 7: Connecting The Ventilation Unit To The Cloud Service

    If this kind of alarm is noticed before fire damage, it can and non-electric be acknowledged by pressing any of the cooker hood buttons . devices are used simultaneously . © Airflow - We reserve the right to make changes without prior notice...
  • Page 8: Main Parts

    DV51 DV51CH MAIN PARTS Adroit DV51 R model in the figure. In the L model, the parts are mirrored . Post-heating resistor Extract air fan Control panel Supply air fan Internal humidity sensor Fine filter for supply air Internal carbon dioxide sensor...
  • Page 9: Main Parts

    Coarse filter for supply air Damper button Coarse filter for extract air Fan speed adjustment Post-heating resistor Light switch Control panel (Optional) Ceiling bushing for electric wires © Airflow - We reserve the right to make changes without prior notice...
  • Page 10: Installation

    . REMOVAL OF CONDENSING WATER Adroit DV51 The Silent Klick siphon is installed in the bottom pool of Adroit NOTE DV51 . The condensing water tube is led from the siphon e .g . to the The Adroit Silent Klick siphon of the sink or to the floor drain.
  • Page 11: Adroit Dv51Ch

    . Observe in the figure: 1 . Elbow . 2 . Exit hole for the condensing water outlet . © Airflow - We reserve the right to make changes without prior notice...
  • Page 12: Installation Of The Adroit Cooker Hood

    DV51 DV51CH INSTALLATION OF THE COOKER CAUTION HOOD The minimum clearance between the bottom The cooker hood is installed on the bottom of Adroit DV51CH . edge of the cooker hood and an electric 1 . Remove the plug from the feedthrough seal of the stove is 426 mm .
  • Page 13: Measuring And Adjusting The Air Flows Of The Ventilation Unit

    . Adjustment: • Cover the required number of holes in the damper with the magnetic strip that is delivered with the cooker hood . © Airflow - We reserve the right to make changes without prior notice...
  • Page 14 A Supply air B Extract air C Cooker hood extract air D Supply air fan E Extract air fan R model in the figures. In the L model, the order of the ducts is mirrored . Adroit DV51 Adroit DV51CH...
  • Page 15: Adroit Dv51, Dv51Ch

    3 . Supply air from the unit to the apartment 4 . Extract air from the apartment to the unit L model A double socket in this area © Airflow - We reserve the right to make changes without prior notice...
  • Page 16: Maintenance

    • Coarse filter for supply air filters insects, heavy pollen filters.airflow.com and other relatively large foreign objects out of the outdoor air . • Fine filter for supply air filters microscopic pollen and dust particles out of the supply air .
  • Page 17: Cleaning The Heat Recovery Cell

    . To check this, WARNING pour some water into the pool . Clean as required . Water must at all times be kept out of the electrical system . © Airflow - We reserve the right to make changes without prior notice...
  • Page 18: Cleaning The Fans

    DV51 DV51CH CLEANING THE FANS IMPORTANT The fans are Check the cleanliness of the fans when servicing the filters and extremely sensitive the heat recovery cell . Clean the fans as required . to external shocks . It is recommended that Removing and cleaning the fans the fans be cleaned in place, i .e .
  • Page 19: Adroit Dv51Ch

    Removing the filter Mounting the filter Light The cooker hood has a long-lasting LED lighting module . If the light is not working, contact a servicing company . © Airflow - We reserve the right to make changes without prior notice...
  • Page 20: Technical Specifications

    DV51 DV51CH TECHNICAL SPECIFICATIONS ADROIT DV51 Product title Adroit DV51CH Adroit DV51 Air volumes Fans Supply air 47 l/sec, 100 Pa Supply air 0 .035 kW 0 .35 A EC Extract air 51 l/sec, 100 Pa Extract air 0 .035 kW 0 .35 A EC...
  • Page 21: Air Flows And Sound Values

    . The sound values increase when the pressure loss in the ducts increase . © Airflow - We reserve the right to make changes without prior notice...
  • Page 22: Internal Electrical Connection

    DV51 DV51CH INTERNAL ELECTRICAL CONNECTION Adroit 51 / Adroit DV51CH Internal electrical connection Vallox 51 MV / Vallox 51K MV / ValloPlus180 MV 1 2 3 4 5 230V 50Hz 130°C 90°C MB_A External Modbus A signal Supply air fan A Motherboard MB_B External Modbus B signal Extract air fan 1.
  • Page 23: External Electrical Connection

    DAMPER CLOSED = CONTACT OPEN DAMPER OPEN = CONTACT CLOSED 3 POTENTIAL FREE CONTACT DATA 24VDC/5A Adroit DV51CH / GUARD Valloplus 180K MV FUNCTION CONTACT Connection card DATA © Airflow - We reserve the right to make changes without prior notice...
  • Page 24: External Electrical Connection

    DV51 DV51CH EXTERNAL ELECTRICAL CONNECTION Adroit DV51 Adroit MyVallox sensor transmitter Potential-free contact Potentiaalivapaa kärkitieto data 24VDC . Can be 24VDC. Voidaan ohjelmoida programmed to display Adroit MyVallox Adroit information such as MyVallox näyttämään esimerkiksi Ethernet connection and Ethernet -liitäntä ja...
  • Page 25: External Electrical Connection

    External temperature sensor connector D/I2 = Digitaalinen tulo 2 11V1 = 11,1V voltin käyttöjännite AN/I = Analoginen sisääntulo 0-10Vdc © Airflow - We reserve the right to make changes without prior notice RM/I = 24V releen sisäänmeno RM/O = 24V releen ulostulo...
  • Page 26: Brine Heat Exchanger

    DV51 DV51CH EXTERNAL ELECTRICAL CONNECTION FOR CONTROLLING THE BRINE HEAT EXCHANGER 24 VDC relay/ Distribution contactor for board controlling the pump and solenoid valve +24VDC Ethernet connection on top of the unit RJ45 Female MLV control Plug connection VENTILATION UNIT INTERNAL ELECTRICAL CONNECTION +24V +24V voltage (DC)
  • Page 27: Duct Radiator Operation

    If an external sensor is in use, it is selected from the settings of the external sensor whether it is used to control the outdoor air Brine heat exchanger or the supply air Brine heat exchanger . © Airflow - We reserve the right to make changes without prior notice...
  • Page 28: Duct Radiator Operation Chart

    DV51 DV51CH BRINE HEAT EXCHANGER In the outdoor air duct In the supply air duct Circulation pump . Not included in the delivery . The pump should be suited to pumping liquid colder than the surrounding air, due to risk of condensation (for example, Grundfos Magna 1 25-80) .
  • Page 29: Exploded View And Parts List

    Adroit VOC sensor Damper motor 60000206 wires 90001241 60000586 (optional) Ceiling feed-through seal Adroit humidity sensor Glass tube fuse 63mA slow Motherboard 60000581 90000612 60000589 (optional) 5x20mm © Airflow - We reserve the right to make changes without prior notice...
  • Page 30: Adroit Dv51Ch

    DV51 DV51CH Adroit DV51CH NO. DESCRIPTION PART NO. NO. DESCRIPTION PART NO. NO. DESCRIPTION PART NO. Post-heating resistor, R model 90001262 Coarse and fine filter Cover door mounting strip 60000590 90001264 Post-heating resistor, L model 90001263 for supply air Door screw (supplied together Adroit VOC sensor with the lock nut of the door 60000561...
  • Page 31: Conformity Certificates

    Managing Director Airflow Developments Limited Aidelle House, Lancaster Road, Cressex Business Park High Wycombe, Buckinghamshire . HP12 3QP, U .K . T: +44 (0)1494 425252 E: info@airflow.com W: airflow.com © Airflow - We reserve the right to make changes without prior notice...
  • Page 32 • Has been installed in accordance with latest Building Regulations and IEEE wiring regulations by a recognised competent installer . Airflow Developments Ltd shall not be liable for any loss, injury or other consequential damage, in the event of a failure of the...

This manual is also suitable for:

Adroit dv51ch

Table of Contents