► Network router . In this case the Adroit unit can be controlled via your laptop, 4. Double click on the Airflow icon. tablet, smartphone etc using a 5. Now you are connected to the Adroit Home service, you are able network created by the router .
DV51 DV51CH Adroit DV51CH CAUTION • Neglecting the The Adroit DV51CH ventilation unit is controlled by using the cleaning of the grease Adroit cooker hood that is connected to the unit . The cooker filter can cause a fire hood is designed to be used above the cooker top, as a general hazard .
DV51 DV51CH MAIN PARTS Adroit DV51 R model in the figure. In the L model, the parts are mirrored . Post-heating resistor Extract air fan Control panel Supply air fan Internal humidity sensor Fine filter for supply air Internal carbon dioxide sensor...
. REMOVAL OF CONDENSING WATER Adroit DV51 The Silent Klick siphon is installed in the bottom pool of Adroit NOTE DV51 . The condensing water tube is led from the siphon e .g . to the The Adroit Silent Klick siphon of the sink or to the floor drain.
DV51 DV51CH INSTALLATION OF THE COOKER CAUTION HOOD The minimum clearance between the bottom The cooker hood is installed on the bottom of Adroit DV51CH . edge of the cooker hood and an electric 1 . Remove the plug from the feedthrough seal of the stove is 426 mm .
Page 14
A Supply air B Extract air C Cooker hood extract air D Supply air fan E Extract air fan R model in the figures. In the L model, the order of the ducts is mirrored . Adroit DV51 Adroit DV51CH...
• Coarse filter for supply air filters insects, heavy pollen filters.airflow.com and other relatively large foreign objects out of the outdoor air . • Fine filter for supply air filters microscopic pollen and dust particles out of the supply air .
DV51 DV51CH CLEANING THE FANS IMPORTANT The fans are Check the cleanliness of the fans when servicing the filters and extremely sensitive the heat recovery cell . Clean the fans as required . to external shocks . It is recommended that Removing and cleaning the fans the fans be cleaned in place, i .e .
DV51 DV51CH TECHNICAL SPECIFICATIONS ADROIT DV51 Product title Adroit DV51CH Adroit DV51 Air volumes Fans Supply air 47 l/sec, 100 Pa Supply air 0 .035 kW 0 .35 A EC Extract air 51 l/sec, 100 Pa Extract air 0 .035 kW 0 .35 A EC...
DV51 DV51CH EXTERNAL ELECTRICAL CONNECTION Adroit DV51 Adroit MyVallox sensor transmitter Potential-free contact Potentiaalivapaa kärkitieto data 24VDC . Can be 24VDC. Voidaan ohjelmoida programmed to display Adroit MyVallox Adroit information such as MyVallox näyttämään esimerkiksi Ethernet connection and Ethernet -liitäntä ja...
DV51 DV51CH EXTERNAL ELECTRICAL CONNECTION FOR CONTROLLING THE BRINE HEAT EXCHANGER 24 VDC relay/ Distribution contactor for board controlling the pump and solenoid valve +24VDC Ethernet connection on top of the unit RJ45 Female MLV control Plug connection VENTILATION UNIT INTERNAL ELECTRICAL CONNECTION +24V +24V voltage (DC)
DV51 DV51CH BRINE HEAT EXCHANGER In the outdoor air duct In the supply air duct Circulation pump . Not included in the delivery . The pump should be suited to pumping liquid colder than the surrounding air, due to risk of condensation (for example, Grundfos Magna 1 25-80) .
DV51 DV51CH Adroit DV51CH NO. DESCRIPTION PART NO. NO. DESCRIPTION PART NO. NO. DESCRIPTION PART NO. Post-heating resistor, R model 90001262 Coarse and fine filter Cover door mounting strip 60000590 90001264 Post-heating resistor, L model 90001263 for supply air Door screw (supplied together Adroit VOC sensor with the lock nut of the door 60000561...
Page 32
• Has been installed in accordance with latest Building Regulations and IEEE wiring regulations by a recognised competent installer . Airflow Developments Ltd shall not be liable for any loss, injury or other consequential damage, in the event of a failure of the...