Service; Installer Settings; Sensor Settings - Trane NEXIA XR724 User's Manual And Installation Instructions

Comfort control
Table of Contents

Advertisement

The following is a guide of the menu options available on screen accessed by pressing the Menu button. Certain
menu selections, which are marked by an asterisk ( * ), may or may not be present depending on other menu settings.

SERVICE

Press and hold Service button for 5 seconds until service menu is displayed

INSTALLER SETTINGS

Setting
Equipment Type

Sensor Settings

Accessories
Comfort Settings
Airflow Settings
Fan type = Non Variable
Fan type = Variable
Hydronic Type = Hydro Air
Lockouts*
Once all selections have been made, press the Done button to exit and return to menu. Press Next to navigate to the next setting.
18-HD82D1-1B-EN
XR724 USER GUIDE
Sub Settings
ODU Type (Outdoor Unit)
ODU Stages
Compressor Type*
IDU Type
Hydronic Type*
ID Heat Stages
ID Fan Type
SOV Operation*
Remote Sensor
ODT Sensor
Aux Relay
Control Option*
Vent Run Time*
Control Response
Dehumidify*
Overcooling Limit*
Smart Cont Fan*
One of the following groups will be
On Delay Cooling
Off Delay Cooling
On Delay Heating*
Off Delay Heating*
On Delay Cooling
Off Delay Cooling
On Delay Heating*
Off Delay Heating*
On Delay Heat
Off Delay Heat
Aux Heat
Aux Lockout ODT*
Comp Heat
Comp Lockout ODT*
None, [AC], HP
[1 Stage], 2 Stages
[1 Comp - 2 Stage], 2 Comp - 2 Stage
[Gas / Oil], Electric, Hydronic
[Hydro Air], Wet Heat
[1 Stage], 2 Stages
[Non-Variable], Variable
[with Cool], With Heat
[None], Replace Indoor, Average
[None], Outdoor
[None], Humidity, Ventilation, Dehumidifier
[With Active Heat], Without Active Heat
[Off], 5 - 60 min in 5 min increments
[Normal], Less Aggressive, More Aggressive (see page 9 for definitions)
[Yes], No
[Off], 1 deg, 2 deg, 3 deg
[No], Yes
displayed
[0], 5-90 Sec in 5 sec increments
[0], 5-90 Sec in 5 sec increments
[0], 5-90 Sec in 5 sec increments
[0], 5-90 Sec in 5 sec increments
Disabled, [Enhanced Mode], 30 sec delay
Disabled, [1.5 Min at 100%], 45 sec delay
Disabled, [Enhanced Mode], 30 sec delay
Disabled, [1.5 Min at 100%], 45 sec delay
[0], 5-90 Sec in 5 sec increments
[0], 5-90 Sec in 5 Sec increments
[No], Yes
30 - 70 Deg [50 Deg]
[No], Yes
5 - 70 Deg, [40 Deg]
Range
7