Heat Pump Wiring Diagrams
Heat Pump Diagram 5: 1 Stage Heat Pump w/GAF2-S Model Air Handler
One stage
Heat Pump
B
R
X2
O
Y
Heat Pump Diagram 6: 1 Stage Heat Pump w/GAF2-36M Model Air Handler
One stage
Heat Pump
B
R
X2
O
Y
Notes:
1. "YI" and "YO" connections must be made as shown for freeze
protection and internally mounted condensate overflow circuits to
work properly
2. If 3rd party condensate overflow switches are installed, they
should be wired between "Y" of the thermostat and "YI" of the
airflow control board
30
XR724 INSTALLER'S GUIDE
Non-VS Air Handler
& Electric Heat
B/C
R
W1
G
Non-VS Air Handler
& Electric Heat
B/C
R
W1
O
G
Y I
(Note 2)
(Note 1)
Y
O
Thermostat Connection
C
R
W1
W2
ODT
ODT
O/B
G
Y1
Y2
Remote Temperature Sensor Connections and Operation:
Sensor Options in the Installer Settings/Sensor Settings menu
Remote Sensor (connect to the RS terminals)
- None
- Replaces internal sensor
- Average with internal sensor
Outdoor Temp Sensor (connect to the ODT terminals)
- None
- Outdoor
Caution: Do not run sensor wires in the same bundle with HVAC
wires. Keep away from high voltage wiring to avoid interference.
Thermostat Connection
C
R
W1
W2
O/B
G
Y1
Y2
Remote Temperature Sensor Connections and Operation:
Sensor Options in the Installer Settings/Sensor Settings menu
Remote Sensor (connect to the RS terminals)
- None
- Replaces internal sensor
- Average with internal sensor
Outdoor Temp Sensor (connect to the ODT terminals)
- None
- Outdoor
Caution: Do not run sensor wires in the same bundle with HVAC
wires. Keep away from high voltage wiring to avoid interference.
BK
RS
Remote
Sensor
RS
Outdoor
Sensor
NO
C
Aux relay
outputs
NC
BK
RS
Remote
Sensor
RS
ODT
Outdoor
Sensor
ODT
NO
C
Aux relay
outputs
NC
18-HD82D1-1B-EN