VMM6 User's Manual_________________________________________
Parameter
High Temperature Soak
Low Temperature Soak
Temperature Cycling (Operating)
Temperature Shock (Storage)
Simulated Solar Radiation
Ignition Protection
Altitude (Transport)
Humidity (Soak)
Humidity - Cyclic
Dust Ingress
Water Ingress
Mechanical Shock - Drop Test
Mechanical - Shock
Mechanical - Bump
Vibration (General)
Vibration (Random)
Vibration (Resonant Search)
Chemical Resistance
Salt Spray
Electrical (Operating Voltage)
Electrical (Over Voltage)
Electrical (Reverse Polarity)
Electrical (Short Circuit)
Electrical (Supply Voltage Test)
Component Test - Electrical
Transients Immunity
Component Test - Electrical
Transients Emissions
Component Test - Electrical
Transients Conducted
Electrostatic Discharge (ESD)
15

Environmental Testing

Standard
EN 60068-2-2:2007
EN 60068-2-1:2007
IEC 60068-2-14:2009
IEC 60068-2-14:2009
EN 60068-2-5:2010
(Procedure B)
ISO 8846
EN 60068-2-13:1999
EN 60068-2-78:2002
EN 60068-2-30:2005
IEC 60529:2001
DIN 40050-9:1993
IEC 60529:2001
EN 60068-2-31:1993
60068-2-27:2009
60068-2-29:1993
60068-2-6: 1996
EN 60068-2-64:1995
(Method 1)
60068-2-6: 1996
ISO 16750-5 (Method 2)
EN 60068-2-52: 1996
for Un=12V and Un=24V
ISO 16750-2
ISO 11452-2:2004
ISO 13766:2006 Section 5
Annex D and Annex E
ISO 7637-2:2004
ISO 10605
Conditions
96hrs. @ 85°C
96 hrs. @ -40°C
-40°C - 85°C (2 cycles of 8 hrs.)
T
= -40°C, T
min
max
10 days @ 40°C
ALT
= Sea Level, ALT
min
RH = 93% +/-3%, Exposure 10 days
RH (> 90%), 6 cycles of 24hrs
Method EN60529 Section 13 Result
IP6X
Method as DIN 40050-9 Result IPX7
500mm free-fall, all faces of 3 axes
2
500m/s
, pulse duration 11ms
2
400m/s
6ms shock pulses, 3 axes
Sine shaped sweep 5 Hz to 500 Hz
Amplitude, 5g, (20 Cycles in each plane)
Random excitation at 10, 150, 220, and
350 Hz breakpoint frequencies, 5 hours
in each axis
frequency range 10 Hz – 2 kHz @ 5G (5
Minutes at each resonant point)
Test method = B
Chamber Temperature = 35°C
(level 4 severity)
Min.: 9VDC Max.: 32VDC
Test for impaired function +24V, +36V
@ 65°C
12V systems: -24V for 5 minutes
Operate at: +16V, +32V
Slow Decrease/Increase: Test
according to ISO16750-2- 4.5
Momentary Drop: Apply the test pulse
according to ISO 16750-2
(Figure 4 for 12V system, Figure 5 for
24V system)
100V/m, 20MHz to
2GHz
Distance of 1 m in the horizontal and
vertical polarization, 30 MHz to 1
GHz
Method as per ISO 7637-2-Annex A2
+/- 8 kV (Direct), +/- 15 kV (Air)