Connection of cable C5 to M12 C01 and M12 C02 connectors

Female 5-pin connector (M12 C01):
Male 5-pin connector (M12 C02):

Parallel connection with Eden, Tina and Spot

Eden can be connected in parallel with a Tina unit, a pair of Spot 10 or another Eden DYN in a safety
circuit, to create a muting/bypass function. M12-3B can be used for an easy connection. For Adam
DYN-Status in StatusBus mode use M12-3S.
A diode, such as a 1N4007, must be inserted with forward current out from pin-4 of the bypassed
Tina or Spot 10 unit.
Diodes are not necessary when two Eden DYN are connected in parallel.

Information output signal attributes

Adam DYN-Info and Adam DYN-Status in non-StatusBus mode are equipped with an information
output on pin-5. When Eva is in contact with Adam, the pin-5 is set high (+24 VDC).
The maximum current consumption for the information output is 15 mA.
Warning! The information output signal is not a failsafe signal and must never be used for the
safety purpose(s).