11 Technical data

Manufacturer
Address
Power supply
Rated operating voltage
Current consumption
Reset indication lamp output
Information output
Electrical data
Voltage drop (DYNlink out)
OFF-state current (DYNlink out)
Transponder frequency
Max. switching frequency
Environmental data
EMC
Ambient temperature
Humidity range
Times
Switch-on delay power on
Response time at activation
Response time at deactivation
Risk time
Useful lifetime / mission time
Mechanical data
Protection class
Enclosure Type Rating:
Material
Connector
Mounting
Weight
Color
Assured release distance (S
Assured operating distance (S
Rated operating distance (S
Hysteresis
2TLC172271M0201
Rev D
ABB Electrification Sweden AB, Jokab Safety
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden
+24 VDC +15 % -40 %
Use SELV/PELV
30 mA at 24 VDC
35 mA at 18 VDC
(45 mA at 12 VDC)
30 mA max on pin 5 (Adam DYN-Reset)
15 mA max on pin 5 (Adam DYN-Info)
2.5V@25mA
<3µA
4 MHz
1 Hz
EN 60947-5-3:2013
Storage: -40...+70°C
Operation: -40...+70°C
35 to 85 % (with no icing or condensation)
2 s
<100 ms
<30 ms
<30 ms
20 years
IP67/IP69K
Type 1
Housing: Polybutylene terephthalate (PBT)
Molding: Epoxy
M12 5-pole male
Torque: 0.6 Nm
Screw torque: 1.0 Nm
Adam: 80 g
Eva: 70 g
Yellow, grey text
)
25 mm
ar
)
10 mm
ao
)
15 +/- 2 mm
n
1-2 mm
30