Elkay EFRC8C-A Installation, Care & Use Manual
Elkay EFRC8C-A Installation, Care & Use Manual

Elkay EFRC8C-A Installation, Care & Use Manual

Fully recessed refrigerated fountain with flexi-guard

Advertisement

Quick Links

EFRC8C-A EFRC8CDC-A EFRC12C-A EFRC12CDC-A LJNE8C-A LJNE12C
Installation/Care/Use Manual
SEE FIG. 9
19, 22
20, 21
EFRC8C, EFRC12C
Installer
To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE
INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION
FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES.
After installation, leave these instructions inside the fountain for future reference.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER
LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY
FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN,
CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL
CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS
INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO
ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
Fully Recessed Refrigerated
Fountain with FLEXI-GUARD
23
SEE FIG. 7
SEE FIG. 8
25
IMPORTANT
IMPORTANT! INSTALLER PLEASE NOTE.
EFRC8CDC, EFRC12CDC
PAGE 1
®
24
SEE FIG. 11
SEE FIG. 9
97162C (Rev. J - 12/15)

Advertisement

loading

Summary of Contents for Elkay EFRC8C-A

  • Page 1 EFRC8C-A EFRC8CDC-A EFRC12C-A EFRC12CDC-A LJNE8C-A LJNE12C Installation/Care/Use Manual Fully Recessed Refrigerated Fountain with FLEXI-GUARD ® SEE FIG. 11 SEE FIG. 9 SEE FIG. 7 SEE FIG. 9 SEE FIG. 8 19, 22 20, 21 EFRC8C, EFRC12C EFRC8CDC, EFRC12CDC Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION.
  • Page 2 EFRC8C-A EFRC8CDC-A EFRC12C-A EFRC12CDC-A LJNE8C-A LJNE12C EFRC8C/EFRC12C ROUGH-IN FINISHED FLOOR LINE FIG. 1 LEGEND: A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2” (38mm) OUT FROM WALL, SHUT OFF BY OTHERS (BOTH SIDES). B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN (BOTH SIDES).
  • Page 3 EFRC8C-A EFRC8CDC-A EFRC12C-A EFRC12CDC-A LJNE8C-A LJNE12C EFRC8CDC/EFRC12CDC ROUGH-IN FINISHED FLOOR LINE FIG. 2 LEGEND: A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2” (38mm) OUT FROM WALL, SHUT OFF BY OTHERS (LEFT SIDE ONLY). B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN (LEFT SIDE ONLY).
  • Page 4: Installation Instructions

    EFRC8C-A EFRC8CDC-A EFRC12C-A EFRC12CDC-A LJNE8C-A LJNE12C INSTALLATION INSTRUCTIONS 1. Remove shipping brace from mounting box and discard. 2. Fasten mounting box into wall cutout using screws or bolts (provided by others) through the holes or knock outs provided on each side of the mounting box. (See Fig. 1 or 2) 3.
  • Page 5 EFRC8C-A EFRC8CDC-A EFRC12C-A EFRC12CDC-A LJNE8C-A LJNE12C EFRC8C EFRC8C W/GLASS FILLER FIG. 3 FIG. 4 EFRC12C EFRC12C W/GLASS FILLER FIG. 5 FIG. 6 PAGE 5 97162C (Rev. J - 12/15)
  • Page 6 EFRC8C-A EFRC8CDC-A EFRC12C-A EFRC12CDC-A LJNE8C-A LJNE12C BASIN BASIN NOTE: WHEN INSTALLING REPLACEMENT BUB- BLER AND PEDESTAL, TIGHEN NUT (ITEM 15) ONLY TO HOLD PARTS SNUG IN POSITION. DO NOT OVER TIGHTEN. FIG. 7 FIG. 8 FIG. 9 97162C (Rev. J - 12/15)
  • Page 7: Dispenser/ Disposal

    EFRC8C-A EFRC8CDC-A EFRC12C-A EFRC12CDC-A LJNE8C-A LJNE12C FIG. 10 DISPENSER/ DISPOSAL FIG. 11 FIG. 12 PAGE 7 97162C (Rev. J - 12/15)
  • Page 8: Parts List

    Tube Assy - GF 56092C Poly Tubing 48”(Cut to Length) PRINTED IN U.S.A. FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 97162C (Rev. J - 12/15) PAGE 8...

This manual is also suitable for:

Efrc8cdc-aEfrc12c-aEfrc12cdc-aLjne8c-aLjne12c