Power Supplies; Airflow Direction; Os6900-X20/X40/X72/Q32/T20/T40 Power Supply - Alcatel-Lucent OmniSwitch 6900 Hardware User's Manual

Hide thumbs Also See for OmniSwitch 6900:
Table of Contents

Advertisement

Power Supplies

Power Supplies
OmniSwitch 6900 power supplies are located at the rear of the switch chassis. Two slots are provided. If a
second power supply is installed, it will assume a standby role.
Please note that the OS6900 does not provide an on/off switch. Connecting an installed power supply to a
power source will boot the switch. Likewise, disconnecting all installed power supplies from a power
source will power off the switch.

Airflow Direction

Power supplies are available in front-to-rear airflow or rear-to-front airflow models. Fan trays are also
direction-specific (front-to-rear or rear-to-front). When installing power supplies, they must match the
airflow direction of the fan tray. (See

OS6900-X20/X40/X72/Q32/T20/T40 Power Supply

Lock Tab
Air Vent
Handle
Model (OS-PS-450W-A)
Product Compatibility
Input Voltage Range
Nominal Voltage
Operating Frequency
Max. Power
Input Current
Output Rating
Ambient Temperature
Humidity (Operating)
Humidity (Non-Operating)
page 3-46
"Airflow Mismatch" on page 3-35
AC Power Supply Front Panel
OS6900-BP-F (YM-2451C), Front-to-Rear
OS6900-BP-R (YM-2451F), Rear-to-Front (Purple Coloring)
OmniSwitch 6900-X20/X40/X72/Q32/T20/T40
90-132VAC; 180-264VAC
115VAC; 230VAC
47-63Hz
450W
8A (90-132V); 4A (180-264V)
2A min to 37A max @ +12V; 0A min to 3A max @ +5VSB
Non-Operating -40C to 70C
95%, non-condensing
95%, non-condensing
OmniSwitch 6900 Hardware Users Guide
Chassis and Power Supplies
for more information.)
Status LED
AC Connector
June 2020

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents